TEKTROL TEK-DP1650A Instruction Manual Download Page 5

Instruction Manual 

Tek-DP 1650A

 

www.tek-trol.com 

Technology Solutions

Warnings and Symbols Used 

The following safety symbol marks are used in this operation manual and on the instrument. 

WARNING 

Indicates a potentially hazardous situation which, if not avoided, could result in 

death or severe injury 

CAUTION 

Indicates a potentially hazardous situation which, if not avoided, may result in 

minor or moderate injury. It may also be used to alert against unsafe practices. 

NOTE 

Indicates that operating the hardware or software in this manner may damage it 

or lead to system failure. 

1.4

 

Packaging, Transportation and Storage 

1.4.1

 

Packaging 

The original package consists of 

1.

Tek-DP 1650A DProbar Multiport Self-Averaging Flow Meter

2. Documentation

NOTE 

Unpack and Check the contents for damages or sign of rough handling. Report damage 

to the manufacturer immediately. Check the contents against the packing list provided. 

1.4.2

 

Transportation 

Avoid impact shocks to the device and prevent it from getting wet during transportation.

Verify local safety regulations, directives, and company procedures with respect to hoisting,

rigging, and transportation of heavy equipment.

Transport the product to the installation site using the original manufacturer’s packing

whenever possible.

Summary of Contents for TEK-DP1650A

Page 1: ...Technology Solutions T 1650A EK DP Instruction Manual DProbar Multiport Self Averaging Flow Meter Document Number IM 1650A www tek trol com...

Page 2: ...contact Customer Support 796 Tek Drive Crystal Lake IL 60014 USA Tel 1 847 857 6076 www tek trol com No part of this publication may be copied or distributed transmitted transcribed stored in a retri...

Page 3: ...n 3 1 4 3 Storage 4 1 4 4 Nameplate 4 2 Product Description 4 2 1 Introduction 4 2 2 Measuring Principle 4 2 3 Dimensional Drawings 5 2 4 Specifications 6 2 5 Model chart 6 3 Installation 8 3 1 Select...

Page 4: ...cation The manufacturer accepts no liability for the consequences of misuse by the operator Wrong installation or operation of the devices systems will cause the warranty to be void The respective Ter...

Page 5: ...er may damage it or lead to system failure 1 4 Packaging Transportation and Storage 1 4 1 Packaging The original package consists of 1 Tek DP 1650A DProbar Multiport Self Averaging Flow Meter 2 Docume...

Page 6: ...he pipe or conduit In a differential pressure flow meter as the liquid passes through the obstruction its potential energy is converted into kinetic energy The velocity of the liquid increases and is...

Page 7: ...flow rate of the liquid using the following formulas To calculate the volumetric flow rate QA N K D2 Faa DP GF For liquids QA N K D2 Faa DP F For gases To calculate the mass flow rate QMASS N K D2 Ya...

Page 8: ...available including Brass steel stainless steel and Hastelloy Bolt Material ASTM A193 B7 ASTM A194 2H ASTM A193 B8M ASTM A194 8MA Process Connection Flanged Weld prepared ends Threaded BSPT Threaded...

Page 9: ...ss Connections A 1 mNPT B 1 150 Flange C 1 weldolet Temperature Measurement O No Temperature Sensor T Integral RTD X Remote thermowell and RTD Flow Transmitters Computers 01 None Customer Supplied 02...

Page 10: ...rdous processes avoid direct contact with the fluid and the meter All installation must comply with local installation requirements and local electrical code WARNING This section offers instructions f...

Page 11: ...stream of Fluid Bar are given in Table 1 Use of recommended straight pipe lengths of uniform diameter ensures that the flow measurement will be made with fully developed characteristics Included gate...

Page 12: ...n Manual Tek DP 1650A www tek trol com Technology Solutions 10 3 1 2 TYPE FBR 73 FBR 75 FLUID BAR 3 1 3 TYPE FBR 76 FLUID BAR Fig 5 Type FBR 73 Fluid Bar Fig 7 Type FBR 76 Fluid Bar Fig 6 Type FBR 75...

Page 13: ...trol com Technology Solutions 11 3 1 4 TYPE FBF 61 FLUID BAR 3 1 5 TYPE FBF 75 FBF 76 FLUID BAR 3 1 6 TYPE FBF 85 FLUID BAR Fig 8 Type FBF 61 Fluid Bar Fig 9 Type FBF 75 Fluid Bar Fig 10 Type FBF 76...

Page 14: ...d support is aligned perpendicular to the pipe axis in line with the weld coupling 5 Install the Flow Tap unit isolating valve on the process connection Verify that the valve is in the fully open posi...

Page 15: ...22mm hole 4 Electrical Connection This section covers the all electrical connection requirement Electrical connection of the device must be carried out by trained qualified specialists authorized to p...

Page 16: ...To ensure meeting stated accuracy alignment must be within limits shown below Pipe size The Fluid Bar may have been designed for a different pipe size than that in which it is being used Measure pipe...

Page 17: ...ts and solutions for process power and oil gas industries Tek Trol provides process measurement and control products for Flow Level Temperature Pressure Measurement Control Valves Analyzer systems We...

Reviews: