![TekPower TP40 User Manual Download Page 46](http://html1.mh-extra.com/html/tekpower/tp40/tp40_user-manual_1077217046.webp)
2. Disconnect test leads and/or any connectors from the
terminals.
3. Use a screwdriver to unlock the four screws on the rear
cover.
4. Take out the rear cover from the meter.
5. Remove the fuse by gently prying one end loose, then
sliding the fuse out of its bracket.
6. Install the replacement fuses only with specified ratings: F
0.63A/1000V
10.3
38
and
F 10A/1000V
10.3
38
7. Rejoin the rear cover and tighten the screws.
5.3 Battery replacement
To avoid false readings, which could lead to
possible electric shock or personal injury,
replace the battery as soon as the battery
indicator (
) appears.
Before replacing the battery, disconnect test
leads and/or any connectors from any circuit
under test, turn the meter off and remove test
leads from the input terminals.
1. Set rotary switch to the OFF position.
2. Disconnect test leads and/or any connectors from the
terminals.
3. Use a screwdriver to unlock the two screws on the battery