![Teknor Industrial Computers TEK-CPCI-1000 Technical Reference Manual Download Page 136](http://html1.mh-extra.com/html/teknor-industrial-computers/tek-cpci-1000/tek-cpci-1000_technical-reference-manual_1077045136.webp)
TEK-CPCI-1000 Technical Reference Manual
F-2
F.2
GENERATE AN EMERGENCY FLOPPY DISKETTE:
Use a system that has a 1.44 Mbytes floppy drive A.
1.
Insert the TEKNOR EMERGENCY diskette in drive A:
2.
Copy the two files WDISK.COM and EMERDISK.TEK from drive A: to your hard
drive (those files are available in your TEKNOR diskette package).
3.
Remove the TEKNOR EMERGENCY diskette and insert a DOS formatted floppy
diskette in drive A:.
4.
At the DOS prompt of your hard drive (same path of the two files WDISK.COM and
EMERDISK.TEK), type WDISK then press Enter.
5.
The program may display one of the following messages:
“Emergency Code transferred”
The emergency diskette has been successfully created. Take the appropriate
actions and restart from the step 4) when you see the following messages.
“Write to disk failure!”
Verify if your floppy diskette is write-protected.
“The file to program in flash was not found”
Be sure that EMERDISK.TEK file is in your current path.
“Unable to read the binary file”
or
“Unable to close the
opened file”
Possible floppy diskette corruption or bad data transfer between floppy disk
and host system.
“Unable to allocate a memory block of 256 Kbytes”
Not enough memory to run the WDISK program.
Summary of Contents for TEK-CPCI-1000
Page 12: ...TEK CPCI 1000 Technical Reference Manual 1 4 TEK CPCI 1000 CompactPCI Block Diagram...
Page 59: ...Setting Jumpers 10 3 10 2 CPU MODEL SELECTION W1 AND W2...
Page 116: ...C 1 C BOARD DIAGRAMS C 1 MECHANICAL SPECIFICATIONS...
Page 117: ...TEK CPCI 1000 Technical Reference Manual C 2 C 2 ASSEMBLY TOP DIAGRAM...
Page 118: ...Boards Diagrams C 3 C 3 ASSEMBLY BOTTOM DIAGRAM...
Page 141: ......