Section:
Description:
Page No:
Date:
SECURE BOTTOM EXTRUSION
CEILING CUT OUT
HAB_302b
3 of 8
Jun 2017
POWER POLE - MID & CEILING FEED
ELECTRICS
STEP 4: Mark Power Pole position on the ceiling using Plum Bob Line. Cut 3-1/2" x 3-1/2"
opening. Measure distance from top of the Lower Power pole Extrusion to the Ceiling. Add
approximately 3" to that dimension and cut Power pole and power pole Cover to that
measurement.
STEP 3: Fasten Bracket to Lower Power Pole.
Power Pole length
= di 3"
3-1/2"
L
M
K
3-1/2"