CCIO-8 Specifications
Mechanical
Dimensions
3.6" x 3.28" x 1.0" (91.5mm x 83.3mm x 25.4mm)
Weight
3.18 oz. (90 g)
Material
Assembled circuit board with aluminum mount frame
Electrical
Voltage Input
20-28 VDC
Output Current Capability
All I/O points 375mA RMS (1000mA peak)
Indicator LEDs for each
input
Yes
IP Rating
IP20
Operating
Temperature/Humidity
-20C to 50C, 0-90% non-condensing
Storage Temperature
-40C to 85C
Power Consumption
100mA@24V or 150mA@12V
Protection Features
Overcurrent protection on all outputs
Inductive clamping on all outputs
ESD protection features on all I/O circuits
Processing /
Communication
Total I/O
Note: All I/O points on CCIO-8 are electrically identical to I/O-1, I/O-2, and I/O-3 on
ClearLink.
8 built-in I/O points, configurable as any combination of up to 8 digital inputs and 8
digital outputs.
A total of 8 CCIO-8 boards can be connected to one ClearLink, for a total of 64
additional digital I/O points.
All I/O hardware is configured via software, i.e., there are no jumpers, DIP switches,
trim-pots, etc.
I/O Update Rate
0.2mS (1-2 boards), 0.4mS (3-4 boards), 0.6mS (5-6 boards), 0.8mS (7-8 boards)
Connectivity
ClearLInk connects to CCIO-8 from its CCIO Port to the COM IN port of the first
CCIO-8. Additional CCIO-8 boards must connect from COM OUT to COM IN. Use