![Teknic ClearLink User Manual Download Page 16](http://html.mh-extra.com/html/teknic/clearlink/clearlink_user-manual_1076592016.webp)
C l e a r L i n k H a r d w a r e M a n u a l / R e v . 1 . 0 0
1 6
T
EKNIC
,
I
NC
.
P H O N E ( 5 8 5 ) 7 8 4 - 7 4 5 4
I/O-0 through I/O-5 configured as DIGITAL OUTPUTS
Note: The wiring shown in this section also applies to all CCIO-8 points
configured as digital outputs.
Output Equivalent Circuit
Typical Actuator Hookup Details
Typical Actuator Hookup Details
Vsupply
(24V)
Vsupply (24V)
*
10k
*
protected FET
0.375A Max.
OUT[NN]
IMPORTANT:
Outputs are “negative true”:
On state turns on transistor, enabling
current in load, pulling output <0.5V
G
S
Coil
Relay
Contactor
Pneumatic Valve
Fluid Valve
Vacuum Valve
Solenoid Guard Lock
Solenoid Actuator
(e.g., diverter)
No Shunt Diode Required
(Outputs have built-in
active clamping)
G
S
M
G
S
DC Motor. Pump, etc.
(single direction)
G
S
G
S
DC Fan
G
S
+
5V/3.3V Logic System
G
S
External clamping diode to logic
supply may be required, consult
logic IC datasheet.
Logic
G
S
G
S
LED Indicator
G
S
G
S
SSR
In
pu
t
Ou
tpu
t
Solid State Relay
G
S
G
S