![Teknic ClearLink User Manual Download Page 10](http://html.mh-extra.com/html/teknic/clearlink/clearlink_user-manual_1076592010.webp)
C l e a r L i n k H a r d w a r e M a n u a l / R e v . 1 . 0 0
1 0
T
EKNIC
,
I
NC
.
P H O N E ( 5 8 5 ) 7 8 4 - 7 4 5 4
Wiring DC Power to ClearLink and CCIO-8
See below for instructions on wiring 24VDC power to ClearLink and CCIO-8.
Tools Required
•
Slotted screwdriver with max. 2mm wide blade
•
Wire
cutter/stripper
•
3-position
screw
terminal
1. Turn off power supply.
2. Strip DC output wires from power supply. Expose
approximately
6.5mm (0.25")
of bare wire.
3. Fully insert V+ and V- wires fully into terminal block "+" and
ground positions.
4. Tighten terminal screws.
5. Inspect connector for good wire capture. Verify that no wire
insulation is captured in the closure, and that no loose wire
strands are sticking out of the connector.
6.
Recommended:
Before connecting the terminal block to
ClearLink, test for correct voltage polarity between "+" and
ground terminals.
Strip Length
0.25 in.
6.5 mm
Tighten screws to
approx. 2 in/lbs.
Use 2mm slotted
screwdriver.
ClearCore/ClearLink
CCIO-8
PWR
From DC
Power Supply
Insert connector(s)
as shown.
Press firmly to seat.
Connecting power to ClearLink and CCIO-8
Chassis Connection
Mount ClearLink and CCIO-8 to a machine frame or chassis continuous with
Protective Earth. Alternately, connect the chassis terminal on the 3-position
power connector to machine frame using conductive hardware.