The plastic hose that is fixed onto the gas entrance of apparatus with a pipe collar, must
be used while connecting for Butane-Propane gas. Connect your apparatus with a short
and impervious hose as much as possible to the gas resource. The hoses permitted
maximum lenght is 1.5m. The hose that brings gas to the apparatus must be changed (1)
once a year for your security.
The points that must be paid attention while connecting the hose;
No parts of the hose must not touch to any place that has heat more than 50
0
C.
The lenght of hose must not exceed 1.5m.
The hose must not be ruptured, be tightened or be folded.
The hose must not touch to the sharp corners, moving things, must not be defective.
The hose must be controlled from end before mounting, it must be observed whether
there is any production defect.
As gas is turned on, all connection parts and hose must be controlled with prepared much
bubbly water at first after the gas entrance connections are completely finished. Never
use a lighter, match,...etc while making this process.
The tightening pipe collars must clear of rust.
The expirence dates must not have exceeded over 5 years.
As affixing an end of hose to the detector, other end to the gas entrance adaptor of oven
tightly, hold it with a sheet iron pipe collar and screwdriver very tightly. If no
connection is made with hose in limitation of conditions that were explained above, flexible
metal hose can be used. It is required to contact to the authorized service to be able to
connect appropriately at security standards on this condition and a technician must do this
connection.
Your oven is adjusted to operate by NG. If it is required to be operated by LPG gas, contact
to the nearest Authorized dealer. While gas is being connected for LPG gas, on the gas
entrance of apparatus,hose connection apparate as described in Figure must be used
and it must be connected by a technician (Figure ). The flexible hose must not syrely
touch to the sharp places and there must be no damage.
ATTENTION!!!
Surely do not use any match and lighter for control of gas leakage.
3.5 ELECTRIC CONNECTION AND SECURITY
During the electric connection, surely follow the instructions below.
The earthing cable must be connected to the terminal. You have to ensure the cable with
insulation to be connected to the power source during the connection of cable. If there is
not any appropriate earthed electric outlet in accordance with regulations in the place where
the apparatus will be installed, immediately contact to our authorized service.
The earthed electric outlet must be close to the apparatus. Surely do not use the extension
cord.
The feeding cable must not touch to the hot surface of the product.
In case the feeding cable is damaged, surely contact to Qualified Service. The cable must
be changed by the authorized service.
The wrong electric connection may damage your apparatus. Such damage is not in
guarantee extent.
The apparatus is adjusted as appropriate for 220-240 Volts of electricity. If the network
electricity is different than this informed value, immediately contact to our authorized
service.
Summary of Contents for GCO3G1P
Page 19: ......
Page 37: ......
Page 55: ......
Page 73: ......
Page 74: ......
Page 75: ......
Page 76: ...TG 66 TG 56 60 60 85 60 60 90 50 60 85 50 60 90 8 8 8...
Page 77: ......
Page 78: ...Air inlet section min 100cm2 Air inlet section min 100cm2...
Page 79: ...COOKER HOOD Min 60 cm Min 42 cm Min 42 cm Min 65 cm with hood Min 70 cm without hood...
Page 80: ......
Page 81: ......
Page 82: ......
Page 83: ......
Page 84: ......
Page 85: ......
Page 87: ......
Page 88: ......
Page 89: ......
Page 90: ...LPG G25 G30 G31 G30 NG G20...
Page 91: ...52018718 10 2008 R000...