teel 4P035A Operating Instructions & Parts Manual Download Page 4

4

Teel Operating Instructions and Parts Manual

4RJ47, 4RJ48, 4RJ49, 4RJ50, 4P035A and 4P036A 

Teel Heavy Duty Cast Iron
Convertible Jet Pumps

®

E

N
G

L

I

S

H

TABLE V    4” DOUBLE PIPE DEEP WELL PERFORMANCE AND EJECTOR CHART – EJECTOR PACKAGE 2P430A

Feet to

Pressure in psi

Pressure in psi

Water

20

30

40

50

20

30

40

50

GPH w/J32P-33 Venturi & #55 Nozzle

GPH w/J32P-33 Venturi & #55 Nozzle

30’

1320

1060

815

580

1490

1200

925

660

40

1160

910

670

440

1310

1030

760

500

50

1030

800

590

385

1160

900

640

400

GPH w/J32P-29 Venturi & #51 Nozzle

GPH w/J32P-29 Venturi & #55 Nozzle

60

600

480

370

260

710

620

510

360

70

525

420

320

230

640

565

450

310

80

465

370

285

200

550

470

355

215

GPH w/J32P-22 Venturi & #53 Nozzle

GPH w/J32P-22 Venturi & #54 Nozzle

90

320

250

190

135

400

345

290

230

100

280

225

170

120

350

300

250

190

110

250

200

155

110

310

265

215

160

Model 4P035A

Model 4P036A

1 HP

1

1

2

HP

NOTE: 

psi = Pounds per square inch (pressure).

TABLE IV    SHALLOW WELL PERFORMANCE AND EJECTOR CHART – EJECTOR PACKAGE 2P429A

Feet to

Pressure in psi

Pressure in psi

Water

20

30

40

50

20

30

40

50

GPH w/N32P-75B Venturi & #57 Nozzle

GPH w/N32P-69B Venturi & #55 Nozzle

5’

1020

1010

975

910

1340

1320

1295

1130

10

910

890

870

830

1200

1190

1180

1130

15

780

760

745

720

1025

1015

995

970

20

650

625

605

575

855

845

835

820

25

470

455

445

425

615

600

590

575

Model 4P035A

Model 4P036A

1 HP

1

1

2

HP

Performance Chart (Continued)

Summary of Contents for 4P035A

Page 1: ...fusers are highly stable high heat thermoplastic Teel convertible jet pump system Model 4RJ49 is a heavy duty convertible jet pump mounted on a 30 gallon horizontal tank Use it on shallow wells up to...

Page 2: ...motor before connecting to power supply Meet United States National Electri cal Code Canadian Electrical Code and local codes for all wiring Follow wiring instructions in this manual when connecting...

Page 3: ...20 30 40 50 20 30 40 50 GPH w J32P 24 Venturi 54 Nozzle GPH w J32P 32 Venturi 55 Nozzle GPH w J32P 24 Venturi 54 Nozzle 30 580 420 260 125 900 660 400 140 1070 865 635 385 40 485 325 180 48 720 520 26...

Page 4: ...0 525 420 320 230 640 565 450 310 80 465 370 285 200 550 470 355 215 GPH w J32P 22 Venturi 53 Nozzle GPH w J32P 22 Venturi 54 Nozzle 90 320 250 190 135 400 345 290 230 100 280 225 170 120 350 300 250...

Page 5: ...40 385 195 370 325 275 235 60 511 486 378 240 585 420 240 66 340 295 250 210 70 438 408 306 186 305 260 220 180 80 354 330 234 132 275 235 195 155 90 240 200 165 125 100 215 180 145 105 110 165 135 10...

Page 6: ...n the venturi with the top hole on the front of the pump See Figure 5 NOTE Always replace the ejector when replacing the pump in a shallow well installation 3 Install the pump in the system Make sure...

Page 7: ...LLATION 2 OR LARGER CASING FIGURE 7 1 Install ejector package 2P429A ejector is included on Model 4RJ49 pump tank system For other heavy duty jet pumps kits are sold separately Follow the instructions...

Page 8: ...lon tape or a teflon based pipe joint compound on threaded pipe joints Protect the foot valve assembly from fish trash etc by installing a screen around it See Figure 9 4 Lower the pipe into the water...

Page 9: ...e from the well to the pump Support the pipe so that there are no dips or sags in the pipe so it doesn t strain the pump body and so that it slopes slightly upward from the well to the pump high spots...

Page 10: ...n tubing from the pump s AVC port to the port on the AVC mounted on the tank See instructions provided with tank and AVC for details You have just completed the tank connection for your jet pump Pleas...

Page 11: ...B L2 L1 A B L2 L1 A B L2 L1 230 Volt to 115 Volt Conversion Spade Connector Type Move black wire from A to L1 1 1 2 2 3 3 230 Volt to 115 Volt Conversion Plug in Type Pull plug straight out from termi...

Page 12: ...d lead in a service panel to a metal underground water pipe to a metal well casing at least ten feet 3M long or to a ground electrode provided by the power company or the hydro authority 4 Connect the...

Page 13: ...rder to get all the trapped air out of the piping Don t forget to close the control valve each time before you start the pump 5 When pressure has built up and stabilized at about 50 psi slowly open th...

Page 14: ...ressure in the system and shut off check the pressure switch operation by opening a faucet or two and running enough water out to bleed off pressure until the pump starts The pump should start when pr...

Page 15: ...er from seal plate See Figure 24 Exposed impeller can now be cleaned 2 If impeller must be replaced loosen two machine screws and remove motor canopy If motor has a capacitor go to step 3 If motor doe...

Page 16: ...piping 11 Prime pump as described under Operation REMOVING OLD SEAL 1 Follow instructions under Pump Disassembly 2 Follow steps 1 through 5 under Cleaning Replacing Impeller 3 Remove rotating half of...

Page 17: ...Operation 4 Check for leaks HELPFUL HINTS HOW TO AVOID OVERPUMPING A SHALLOW WELL In the section on Priming the Shallow Well Pump the instructions were to open the control valve all the way after the...

Page 18: ...ve assembly L262 4PS L262 4PS L262 5PS L262 5PS L262 5PS 1 12 Pump body L76 48A L76 48A L76 49A L176 40 L176 40 1 13 1 4 NPT Drain plug 1 14 1 8 NPT Pipe plug 1 15 1 4 NPT Barbed fitting st 1 16 Switc...

Page 19: ...r bushing 1 7 1 NPT Pipe plug 1 8 1 8 NPT Bayonet fitting 1 9 AVC Tube U37 626P 1 10 Air volume control U238 4 1 11 1 4 NPT Bayonet elbow 1 12 1 4 NPT x 11 2 Nipple 1 13 3 8 16 x 11 4 lg Carriage bolt...

Page 20: ...s on nozzle instead of part number 1 Check valve assembly N212 12P 1 2 1 8 NPT sq hd teflon taped pipe plug 2 3 Ejector body N40 92 1 4 Nozzle 1 each 55 J34P 45 1 51 J34P 41 1 5 Gasket N20 25 1 6 Vent...

Page 21: ...ler is plugged 3 Clean ejector or impeller see Maintenance 4 Check or foot valves stuck in closed 4 Replace check valve or foot valve position 5 Frozen pipe 5 Thaw pipes Bury pipes below frost line He...

Page 22: ...m Certain aspects of disclaimers are not applicable to consumer products e g a some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages so the above limitatio...

Reviews: