32
www.teejet.com
OVER
VIE
W
SE
TUP
APPENDIX
GE
TTING ST
AR
TED
OPER
ATION
ISOBUS Job Computer : IC18 Sprayer
Start/Stop Application
When a switchbox is not connected for boom section control, starting/stopping application is controlled using the Start/Stop Key.
Without Switchbox
Figure 4-13: Spraying Stopped
C n t 1
5 . 0
2 5
2 0 l
0
b a r
0 . 2 5 h a
1 3 11
l / h a
k m / h
Figure 4-14: Spraying Started
C n t 1
5 . 0
2 7 . 8
2 0 l
3 8
b a r
0 . 2 5 h a
1 3 11
l / h a
k m / h
• To start or stop the application, press the START/STOP KEY
.
With Switchbox
If a switchbox is being used to control the boom sections, starting/stopping
application will be controlled by the switchbox.
Figure 4-15: Operations Screen With Switchbox
C n t 1
0 . 0
2 5
0 l
0
b a r
0 . 0 0 h a
1 3 11
l / h a
k m / h
Master Stop Key
Figure 4-16: Spraying In Progress
C n t 1
5 . 0
2 6 . 7
2 0 l
3 8
b a r
0 . 2 5 h a
1 3 11
l / h a
k m / h
Figure 4-17: Master Stop Pressed
C n t 1
5 . 0
2 5
2 0 l
0
b a r
0 . 2 5 h a
1 3 11
l / h a
k m / h
Master Stop Key is used to stop all application, close all regulation valves and
change to manual regulation mode.
•
To stop all application, close all regulation valves and change to manual
regulation mode, press the STOP KEY .
This is designed to be like an emergency stop button.
With Switchbox
If a switchbox is being used to control the boom sections, the Master Stop Key will
override the Master Switch on the switchbox and turn off any boom application in
progress.
Summary of Contents for ISOBUS IC18
Page 1: ...U S E R M A N U A L IC18 SPRAYER JOB COMPUTER Software version 1 06 ...
Page 5: ......
Page 44: ......