The Challenger
Version 8.0 User Guide : Issue I , Revision I : October 1997
PANEL STATUS
- Menu Option 1
This function is used to list any inputs which are in alarm, in tamper alarm, isolated or unsealed and any system alarms.
There are menu options available which display each of these conditions separately, however this option may be used to
check on all inputs which need attention.
The status is shown by the letter preceding the input number:
A =
Alarm
An alarm has occurred at this input and it should be acknowledged and reset.
Refer to the section - Alarm.
T =
Tamper Alarm
An alarm has occurred at this input due to tamper or accidental damage. The alarm should
be acknowledged and reset. Refer to the section - Alarm.
i
=
Isolated
The input has been excluded from functioning as part of the security system and is probably
broken or faulty.
U =
Unsealed
The input is activated and needs to be checked and sealed if necessary to ensure security is
maintained. eg. Close door.
No inputs in alarm, tamper alarm, isolated or unsealed:
The display will show:
No Alarms, Tampers, Isolates, Unsealed
Press ENTER
ENTER
~
Return to the menu.
or
NEXT
~
Update the status.
Inputs in alarm, tamper alarm, isolated or unsealed are listed either:
One at a time
eg.
Summary On U2. Front Door Contact
NEXT or ENTER
or
As a list of numbers
eg.
Summary On U1, A3, T4, i5, i9.
Input No:
From either display:
NEXT
~
Update the list of inputs and display the next inputs in the list (if any).
or
ENTER
~
Return to the menu.
or
? ENTER
~
Display the input name in full.
Note:
Using Panel Link changes the standard numbering system seen here, to reflect that of Panel Link's system.
\See Also:
Alarm Types
Inputs Unsealed - Menu Option 2
Inputs in Alarm - Menu Option 3
Inputs Isolated - Menu Option 4