(fig.47b); normally this unit is pre-calibrated to a pressure of 10Bar, with SAE20 viscos
-
ity lubricant in order to make a drop of lubricant come out, which can be seen from the
specific cover, every 4 times the bead breaker is operated.
Periodically check the lubricant level through the specific windows and top up as shown
in fig.47c. Top up only with non-detergent SAE20 oil equal to 50cc.
The filter regulator “FR” has an automatic condensation drain system, therefore in condi
-
tions of normal use special maintenance is not required. The condensate may however
be drained manually at any time (fig.47d). Normally the cups do not need to be removed,
but check if this is necessary for maintenance operations after a long period of use. If a
manual operation is not sufficient, use the specific key provided (fig.47e).
Clean with a dry cloth. Avoid contact with solvents.
NOTE
: for oil warnings, refer to the specific chapter in the machine user manual.