INSTALLATION
CH 3
3. [ INSTALLATION ]
3.1 Cleaning
The magnet yokes show large attraction forces on all soft
magnetic objects such as iron. These forces cannot be controlled
by hand. They may cause serious jamming danger.
Do not bring any soft magnetic objects (iron) nearer than 1m of
the magnetic side of the magnet yoke.
Magnetic sensitive objects like banking cards, pacemakers or
other magnetic information carriers may be damaged if they are
brought within 25cm of the magnet yokes.
The magnet yoke and coil unit can be damaged when cleaned
with a non-prescribed cleaning agent.
Use only Isopropanol as a cleaning agent.
For general, non-cleanroom applications, the magnet yokes and coil units
do not need to be cleaned intensively.
For cleaning purposes Tecnotions prescribes Isopropanol as cleaning agent
for the magnet yoke and coil.
3.2 Cleanroom cleaning
For cleanroom applications Tecnotion products need to be cleaned additi-
onally to remove dust particles.
3.2.1 Tools
■
Isopropanol cleaning wipes
■
Filtered pressed air installation
■
Blacklight installation
■
UV Glasses
■
Cleanroom compatible vacuum cleaner
■
Cotton swap