DIGITAL HALL MODULE
AP C
A
3-1
2-3
1-2
Induced voltage moving in cable direction
Phase 1 (+) - Phase 2 (-)
2
1
0
-1
-2
0 1.4 2.8 4.2 5.5 6.9 8.3 9.7 11 12.4 13.8 15.2 16.5
MOVEMENT OF ONE POLEPITCH IN CABLE DIRECTION (mm)
B
3 DIGITAL OUTPUTS A,B,C:
- SINK-TYPE 20mA max.
- PERIOD 16.5mm (UC SERIES)
- SIGNAL DEFINITION ACCORDING TO FIGURE (HIGH=SINK)
- MAXIMUM VOLTAGE DROP 0.4V + 120 * Isink (in A)
- TYPICAL VOLTAGE DROP 0.1V + 120 * Isink (in A)
- SHORT CIRCUIT SAFE @5V SUPPLY
POWERSUPPLY
- +4.5 .. + 28V DC
- 40mA
CABLE CONNECTIONS
C
WHITE BROWN
GREEN YELLOW GREY
PINK
BLUE
RED
SHIELD
0 V
+4.5 .. 28V GND
HALL C
HALL A GND
GND
HALL B GND
Only one ground wire needs to be connected for proper grounding.
APPENDIX C
Digital Hall Module - UC
Cable 1.0M
Put the PCB, which is sticking
out, against casting of the Coil
Unit at the cable side.
Then mount the Digital Hall Module
to the construction.
11.75
8
2.5
(2
x)
M3 (2x)
18.5
d
8
O
2.9
M3 (depth 3) (2x)
4
(2
x)
Coilunit
Dimension d (mm)
UC3
10.5
UC6
11.5