II_DigiTech_05_eng
15 of 20
Installation instructions
DigiTech
It’s possible to connect a relocker to the lock cover through the appropriate holes.
Functional test
To be carried out with the door open.
MEMBRANE TEST:
Press and hold the button 5 to access the "Membrane Test" function.
Press slowly all the buttons according to the sequence shown on the display.
ELECTRONIC / MECHANICAL TEST:
OPENING:
Enter the opening code (standard manager code 123456). The display will show "open" and the
green LED will light up.
With SwingBolt and MotorLock locks, turn the safe door handle to the open position.
With DeadBolt and LatchBolt locks, rotate the knob or handle according to the type of installation
and move the lock bolt to the open position.
For all types of locks the bolt must be able to move freely.
LOCKING:
With SwingBolt and MotorLock locks, turn the safe door handle to the locked position. Lock bolt
must fully extend and ensure locking.
With MotorLock locks with manual relocking, turn the door handle towards the locked position
and press the button
.
Lock bolt must fully extend and ensure locking.
With DeadBolt lock, rotate the knob or handle according to the type of installation and move the
lock bolt to the locked position.
Lock bolt must fully extend and ensure locking.
Make sure that there is free space in all directions around the bolt when the movement is
brought to the locked position.
Repeat the functional test several times before closing the safe door.
Failure to follow these installation instructions or opening the lock by personnel not
authorized by Tecnosicurezza will void the warranty
Fix the relocker plate with M4 self tapping flat head screws.
Length must be 6 mm + plate thickness.
(i.e. 6 mm + 2 mm plate = 8 mm screw)