15
ENGLISH
The
Skip
Function
only
intervenes
until
it
reaches
the
subsequent
programmed
switching
point.
At
this
point
the
Skip
Function
is
cancelled
and
the
programmed
switching
cycles
are
activated
once
again.
Programming
Errors
If
"EEE"
appears,
there
is
a
setting
error.
The
number
of
the
switching
cycle
with
the
error
is
displayed.
Move
the
setting
switch
to
P.
Press
the
button
until
it
displays
the
cycle
with
the
error.
Correct
it
and
then
move
the
setting
switch
to
“RUN”
to
exit
the
programming
mode.
Every
switch
‐
on
point
is
linked
to
the
subsequent
switch
‐
off
point.
Therefore
the
following
ON/OFF
combinations
can,
for
example,
lead
to
errors.
Possible
causes
of
errors:
Activation
ON
Deactivation
OFF
a)
Programmed
switch
‐
on
No
setting
b)
No
setting
Programmed
deactivation
c)
Day
block
(e.g.
1,
2,
3,
4,
5)
Different
day
block
(e.g.
1,
2,
3,
4,
5,6)
d)
Day
block
Day
of
the
week
e)
Programmed
time
activation
(e.g.
Wednesday,
09:00)
Deactivation
of
the
set
time
is
prior
to
the
activation
time
on
the
same
day
(e.g.
Wednesday,
08:59)
f)
Switch
on
and
off
set
at
same
times
(e.g.
Wednesday,
09:00)
Technical
Data
of
programmer
Daily
and
weekly
programming
of
16
switches
per
channel
(8
x
ON,
8
x
OFF).
With
day
block
programming,
there
are
56
switch
possibilities.
The
minimum
time
interval
between
switching
points
is
1
minute.
Lithium
battery
(3Vdc)
lasting
up
to
5
years
without
power
supply.
Ambient
temperature:
‐
10°C
to
+55°C
(T
‐
10;
T55).