background image

5750 204 493

Printed in Germany    0504 Es.

Summary of Contents for Cooker hood

Page 1: ...How to use and look after your built in cooker hoods ...

Page 2: ...2 mind 650 mind 550 Abb 1 ELECTR Fig 1 GAZ ...

Page 3: ...res such as reciprocal interlocking etc If the air intake is inadequate there is a risk of poisoning from combustion gases which are drawn back into the room An air intake exhaust air wall box by itself is no guarantee that the limiting value will not be exceeded Note When assessing the overall requirement the combined ventilation system for the entire household must be taken into consideration Th...

Page 4: ...ified specialist Dispose of packaging materials properly see Installation instructions Light bulbs must always be fitted when the extractor hood is in use Defective bulbs should be replaced immediately to prevent the remaining bulbs from overloading Never operate the extractor hood without a grease filter Overheated fat or oil can easily catch fire If you are cooking with fat or oil e g chips etc ...

Page 5: ... cleaned after 8 to 10 weeks The filters can be cleaned in a dish washer It is however possible that they will become slightly discoloured The filter must be placed loosely and NOT wedged in the dishwasher Important Metal filters that are saturated with grease should not be washed together with other dishes etc When cleaning the filters by hand soak them in hot soapy water first of all Then brush ...

Page 6: ... filters are available from specialist outlets see Optional accessories Use only original filters The appliance is then guaranteed to function perfectly Disposal of old activated carbon filters Activated carbon filters do NOT contain any harmful substances They can therefore be disposed of as household refuse 2 Clean the filters 3 Insert the clean filters back into the hood Activated carbon filter...

Page 7: ...etergent solution or a mild window cleaner to clean the canopy of the extractor hood Do not scrape off any dirt that has dried on but loosen it up with a damp cloth Do not use abrasive cleaning agents or sponges that could cause scratches Note Do not use alcohol spirit on plastic parts otherwise the surface may become matt in appearance Caution Ensure that the kitchen is ade quately ventilated Avo...

Page 8: ...am will cause condensation to form on the hood Old appliances are not worthless rubbish If they are disposed of in an environment friendly manner valuable raw materials can be recovered for use again Before you dispose of an old appliance make sure that it has been rendered inoperative Your new appliance was protected on its way to you by the packaging None of the materials cause pollution to the ...

Page 9: ...is an adequate supply of fresh air which will be needed by the burner for combustion Safe operation is possible provided that the underpressure in the room where the burner is installed does not exceed 4 Pa 0 04 mbar This can be achieved if combustion air can flow through non lockable openings e g in doors windows and via the air intake exhaust air wall box or by other technical measures such as r...

Page 10: ...he extractor hood unless there is already one fitted in the outlet duct or wall ventilation box If no one way flap was enclosed with the hood it can be obtained from a specialist retailer Installing the one way flap Snap the one way flap into the air pipe The two lightly sprung flaps must be able to move upwards If the exhaust air is going to be discharged into the open a telescopic wall box shoul...

Page 11: ...n 51 318 max 1080 mind 813 170 250 323 500 522 600 700 900 1000 1100 Weight in kg Exhaust air Recirculating air 12 5 060 cm 070 cm 13 5 13 0 14 0 090 cm 13 9 14 9 100 cm 14 5 15 5 110 cm 15 0 16 0 We reserve the right to construction changes within the context of technical development Preparing the wall The wall must be flat and perpendicular Ensure that the wall is capable of providing a firm hol...

Page 12: ...s If possible site the earthed socket directly behind the chimney panelling Electrical data Are to be found on the name plate inside the appliance after removal of the filter frame Before undertaking any repairs always disconnect the extractor hood from the electricity supply Length of the connecting cable 1 30 m If it is necessary to wire the extractor hood directly into the mains The extractor h...

Page 13: ...c hob and 650 mm for a gas hob The bottom edge of the template equates to the lower edge of the extractor hood 4 Drill 5 holes dia 8 mm for the extractor hood and 4 holes dia 8 mm for the brackets for fixing the flue ducts and insert wall plugs flush with the wall Note Take into account any special accessories that are going to be fitted 5 Screw on the 2 brackets for fixing the upper and lower flu...

Page 14: ... duct when pushing on the lower duct cover the edge of the lower duct with the installation template or other protective material Then screw the flue duct to the sides of the fixing bracket with 2 short screws Before tightening the 2 screws align the flue duct 14 Re insert the grease filter see operating instructions 1 2 11 Stainless steel model Remove the protective film from the two flue ducts T...

Page 15: ...l be made to the customer either at the time of visit or at a later time in administration OVENS ONLY Heating appliances will rise in temperature within use and retain their heat for a long period after use Children should be supervised at all times and should not be allowed to touch the surfaces or be in the vicinity of the appliance when in use up until the time the appliance has cooled after us...

Page 16: ...5750 204 493 Printed in Germany 0504 Es ...

Reviews: