Instructions for the installation, use and maintenance of Tecnicomar watermaker
3-14
ONLY FOR CAT PUMP
Be sure that the high pressure pump (F) has enough oil for correct operation. The correct oil level
must reach the red point on the glass bezel (F1) in the rear of the pump. Use the valve (F2) to
change oil (refer to the MAINTENANCE section). Remove the sticker from the pump oil plug
ONLY FOR CAT PUMP
To ensure good lubrication the PUMP must
be installed in an horizontal base. Use oil
supplied by Tecnicomar only!
Figure 4 - oil valve and level mark on CAT pump