- 16 -
Mount the modules directly across from each other using a square or common reference point.
The mounts should also be centered between the closest idlers on either side of the weighing
idler(s). Once centered and squared tighten down the mounting bolts for the left and right
modules.
You can now place the modified idler on top of the mounting pads. Make sure the belt direction
of the idler is correct. Assemble the idler hold down clamps with the carriage bolts and hardware
supplied. Only finger tighten at this point. Loosen the mounting bolts on the end of the load
cells with the rigid mount on them. Just enough to allow the mounting pad to settle and come
into full contact with the inverted angle of the CEMA idler.
For HY25 dual idler installations repeat this process for the second idler.
Note that if the structure is truly flat and square the idler(s) that have now been mounted on the
modular scale assemblies is approximately 1/8” higher than the adjacent idlers. This is not
always the case but the following instructions are based on this assumption. Adjustments and
shim size references may need to be different in your specific application.
Now align the weigh idler with the three idlers on either side of the scale using the fish line and
shims provided. Perform the instructions following and refer to the diagram below.
1) Loosen the two idlers before and after the scale.
2) Shim the +2 and -2 idlers up 3/16 of an inch, center them on the stringer, and re-tighten the
bolts.
3) Stretch three fish lines across the idlers centered on the +/- 2 roller center marks.
Summary of Contents for Tecweigh 20
Page 2: ... 1 ...
Page 10: ... 9 2 09 I O Quick Reference Guide ...
Page 20: ... 19 ...
Page 24: ... 23 4 03 WY15 and WY25 Scale Wiring load cells ...
Page 25: ... 24 4 04 HY15 and HY25 Field Wiring ...
Page 26: ... 25 4 05 WY10 WY10HD and WY20 Scale Wiring LVDTs ...
Page 27: ... 26 4 06 Chart Recorder Data Logger using the 4 20 ma output ...
Page 28: ... 27 4 07 Chart Recorder Data Logger using the HFR output ...
Page 29: ... 28 4 08 Remote Rate Total Display 4 09 Remote Tons Counter ...
Page 30: ... 29 4 10 Radio Transceivers Local Scale Remote Processor ...
Page 31: ... 30 4 11 Radio Transceivers Local Processor Remote PLC PC or Remote Display ...
Page 32: ... 31 4 12 Radio Transceivers Local DC Generator Remote Processor ...
Page 33: ... 32 4 13 Radio Transceivers Local DC Generator and Processor ...
Page 34: ... 33 4 14 Multiple Processors to Tecweigh Multi Scale Display MSD ...
Page 61: ... 60 SC300 PCB WY15 and WY25 SC400 PCB WY10 and WY20 ...
Page 71: ... 70 10 01 WY10 Dimensions CHAPTER 10 DIMENSIONS ...
Page 72: ... 71 10 02 WY10 HD Heavy Duty Dimensions ...
Page 73: ... 72 10 03 WY15 Dimensions ...
Page 74: ... 73 10 04 WY20 Dimensions ...
Page 75: ... 74 10 05 WY25 Dimensions ...