Electrostatic Discharge Prevention 

Electrostatic discharge may damage devices and circuits. Improper treatment may 
cause the router to malfunction completely or discontinuously. 

Move or locate the devices according to the measures of electrostatic discharge 
prevention, ensuring the chassis connects the ground. Another measure is to wear the 
static-proof hand ring. If there is no hand ring, use the metal clip with the metal cable to 
clip the unpainted metal part of the chassis. In this case, the static is discharged to the 
ground through the metal cable of the clip. You can also discharge the static to the 
ground through your body. 

2.3    Requirements for Common Locations 

This part describes the requirements for the installation locations. 

2.3.1   Environment 

The router can be installed on the desk or the cabinet. The location of the chassis, 
cabinet planning and indoor cabling are very important for normal system’s function. 
Short distance between devices, bad ventilation and untouchable control plate will 
cause maintenance problems, systematic faulty and breakdown. 

For location planning and device locating, refer to section 2.3.2 “Location Configuration 
Prevention”. 

2.3.2   Location Configuration Prevention 

The following preventive measures assist you to design the proper environment for the 
router. 

z

 

Make sure that the workshop is well-ventilated, the heat of TX devices is 
well-discharged and sufficient air circulation is provided for device cooling.   

z

 

Avoid to damage devices by following the electrostatic discharge prevention 
procedure. 

z

 

Put the chassis at the place where cool air can blow off the heat inside the 
chassis. Make sure the chassis is sealed because the opened chassis will 
reverse the cool air flow.   

2.3.3   Cabinet Configuration 

The following content assists you to make a proper cabinet configuration: 

z

 

Each device on the cabinet gives off heat when it runs. Therefore, the sealed 
cabinet must have the heat-discharge outlet and the cooling fan. Do not put the 
devices too close, avoiding bad ventilation. 

z

 

When you install the machine box at the open cabinet, prevent the frame of the 
cabinet from blocking the airway of the machine box. 

Summary of Contents for TSR 2800-20-DC

Page 1: ...TSR 2800 20 DC Router s Hardware Installation Manual...

Page 2: ...3 1 Installation Procedure of TSR 2800 20 DC Router 9 3 2 Installing Router s Hull 9 3 2 1 Installing the Chassis on the Desk 10 3 2 2 Installing the Chassis on the Cabinet 10 3 3 Connecting the Port...

Page 3: ...th a rate of 1200bps to 57600bps which has no indicators USB port USB1 1 interface which has a rate of 1 5Mbps in low speed mode and a rate of 12Mbps in full speed mode There are also four interface c...

Page 4: ...er is shown in the following figure Table 1 3 Parts at the front template of TSR 2800 20 DC router No Abbrev Name Remarks 1 GND Grounding column The grounding must be fine 2 SLOT4 Slot 4 for expanded...

Page 5: ...e USB port 4 slots for interface card that is 2 slots for Network Interface Card NIC and 2 slots for expanded interface card Dimensions 442 5mm 425mm 44mm Working temperature humidity 0 40 10 85 non c...

Page 6: ...TSR 2800 20 DC Router s Hardware Installation Manual 4 1 3 ROHS Description...

Page 7: ...do not insert the console cable into the Ethernet twisted pair port RJ45 8 line socket Note 1 When you plug or dial out the power line keep the power line horizontal with the power socket 2 When the l...

Page 8: ...eside the power source z When the power is on do not touch the power z Correctly connect the device and the power socket z Only professionals are allowed to operate and maintain the device z Read the...

Page 9: ...evices bad ventilation and untouchable control plate will cause maintenance problems systematic faulty and breakdown For location planning and device locating refer to section 2 3 2 Location Configura...

Page 10: ...an be installed if necessary At least a 240 V and 10A fuse or a breaker is provided in the phase line if you prepare the short circuit prevention measures for a building Caution If the power supply sy...

Page 11: ...rocedure of TSR 2800 20 DC Router 3 2 Installing Router s Hull The hull of the router can be installed on the desk or can be fixed to other cabinets Your network installation requirements can be met i...

Page 12: ...he brackets the front template of the router faces forward The detailed operations are shown in the following figure Note The previous example only describes how to install the router s hull on one si...

Page 13: ...h specific monitor cable and then run terminal imitation software Windows super terminal The cable is provided according to the host The communication parameters of the terminal serial port can be set...

Page 14: ...e terminal device One end of the cable is a 8 pin RJ45 plug and the other end is a 9 hole plug DB9 The RJ45 plug is put into the socket of the console port on the TSR 2800 20 DC modularized router The...

Page 15: ...the data TPTXD Output 2 Sending the paraphase of the data TPTXD Output 3 Receiving the normal phase of the data TPRXD Input 6 Receiving the paraphase of the data TPRXD Input 3 Outside line connection...

Page 16: ...be saved during network connection However HUB must be used when more than two Ethernet UTP ports are interconnected See the following figure for UTP connection Note The color arrangement of UTP conn...

Page 17: ...ectly insert NIC into a slot Type of NIC Slot1 Slot 1 for interface card Slot2 Slot 1 for interface card Slot3 Slot 1 for interface card Slot4 Slot 1 for interface card No Module ID 1 Single path E1 c...

Page 18: ...en the cover of the router required tools and operation methods Caution When the power cable still connects the power source do not touch it When you open the cover the router you may use the followin...

Page 19: ...r uninstall and install SDRAM according to the following steps Turn off the power on off of TSR 2800 20 DC router and plug out the power plug Find the SARAM SIMM slot on TSR 2800 20 DC router accordin...

Page 20: ...cked Slowly break off the pinchcock at both sides of the SDRAM SIMM slot according to the previous method After taking off the original SDRAM bar make the brim of the gold finger of the SDRAM bar poin...

Page 21: ...d install the hull according to the procedure of closing the hull 4 3 Closing Chassis The section mainly describes how to put the cover and close the chassis Do as follows z Put them well according to...

Page 22: ...et and air inlet are clean and then do relative operations in section Requirements for Common Locations The working temperature of the router is from 0 to 40 Celsius degrees z If the router cannot be...

Page 23: ...e copy or change partial or all contents of this manual and must not broadcast it in any manner Trademark claims Trademarks product names service names and company names which are written in this manu...

Reviews: