DUT-E installation / Monitoring of two and more tanks / DUT-E 232 readings totalizing
DUT-E fuel level sensors. Operation manual. Version 8.1
©
Technoton, 2020
39
Table 8
—
DUT-E SUM 232 wires assignment
Wire number
Wire marking
Wire color*
Assignment
1
VBAT
Orange
Power supply “+”
2
GND
Brown
Ground
“
-
”
3
232R
White
Received data
(RS-232)
4
232T
Red
Transmitted data
(RS-232)
*
reserves the right to change wire colors.
To get correct values DUT-E 232 sensors should be configured with
software
according to the following instructions (see
)):
1)
For data output in
upon request
mode the following parameters must be applied for
all
the sensors:
•
Automatic transmission mode
switched
Off
(
Operation modes
module);
•
Output message
selected as
Volume (L)
(
Output message
module).
2)
For data output in
automatic
mode the following parameters must be applied:
•
for
all
the sensors
—
Output message
selected as
Volume (L)
(
Output message
module);
•
sensor
N
1
—
Automatic transmission mode
selected as
HEX
,
Message Interval
(s)
value is 1 (
Operation modes
module);
•
sensors
N
2
…
N
(n-1)
—
Automatic transmission mode
switched
Off
(
Operation
modes
module);
•
sensor
N
n
(the last one)
—
Automatic transmission mode
set to
HEX
\
ASCII
\
ASCII
EXT
,
Message Interval
(s)
set any required by the tracking device value
(
Operation modes
module).
Note
—
for sensor
N
n
(the last one) at least 8 second message interval is recommended.