1.4.4 Specifications of DUT-E 232/485 output signal
Specifications of DUT-E 232 and DUT-E 485 output signal correspond to the specifications of
RS-232 and RS-485 interfaces.
Depending on settings output value of DUT-E 232 and DUT-E 485 can stand for:
•
standard (normalized) units, from 0 to 1000 (0
–
empty tank, 1000
–
full tank);
•
fuel level in the tank (mm);
•
fuel volume (l);
•
percentage of full tank capacity (%).
DUT-E sensor sends data on current temperature as well (value is measured with the
temperature sensor located on the PCB).
DUT-E 232 and DUT-E 485 data transfer is carried out according to