DUT-E installation / Monitoring of two and more tanks / DUT-E 232 readings totalizing
DUT-E fuel level sensors. Operation manual. Version 8.1
©
Technoton, 2020
38
2.8 Monitoring of two and more tanks
2.8.1 DUT-E 232 readings totalizing
is used together with DUT-E 232 sensors on
vehicles with two and more fuel tanks for measuring total amount of fuel (see figure 22).
ATTENTION:
1)
DUT-E SUM 232 summator operates only with DUT-E 232 sensors with firmware
version 3.0 and higher.
2)
Fuel tank calibration table should be recorded into the internal memory of each
Figure 22
—
DUT-E SUM 232 summator
DUT-E SUM 232 output message contains total fuel volume (in liters) as a sum of the values
measured by sensors connected to its
IN
and
IN/OUT
inputs.
Electrical connection of summators is carried out according to the diagrams provided in
figure 23 and in compliance with wire assignment provided in table 8.
sensors are connected to the single tracking device according to figure 23 a.
If there are three or more fuel tanks to be measured with DUT-E 232 sensors, cascade
connection can be used according to figure 23 b.
Quick splice connectors
(ordered separately) are recommended for electrical connection of
signal wires.