![Technotherm PH Ultraslim Instruction Manual Download Page 8](http://html.mh-extra.com/html/technotherm/ph-ultraslim/ph-ultraslim_instruction-manual_1070656008.webp)
Feel good through warmth from electricity - www.technotherm.de
Instruction Manual - PH Ultraslim
Feel good through warmth from electricity - www.technotherm.de
GB
8|
* Pay attention:
Ensure that you have all necessary elements to re-setup your installation before to use this
function.
12 Software version
_._
13
End
: Exit the parameter’s menu
Press (OK) key to exit installation parameter menu and return to normal operation.
7. TECHNICAL CHARACTERISTIC
Measured temperature precision
0.1°C
Environmental:
•
Operating temperature
•
Shipping and storage temperature
0°C - 35°C
-10°C to +50°C
Setting temperature range
•
Comfort, Reduced
•
Timer
5°C to 30°C by 0,5°C step
5°C to 19°C by 0,5°C step
Regulation characteristics
Proportional band (PWM)
Power Supply
/- 10% 50Hz
Output
•
Maximum Load (Resistive only)
TRIAC 230Vac
10 Amps (2000W)
Software Version
Displayed in the user menu.
Norms and directives:
Your thermostat was designed in accordance with the follo
-
wing Europeans norms and directives:
EN 60730-1 : 2003
EN 61000-6-1 : 2002
EN 61000-6-3 : 2004
EN 61000-4-2 : 2001
Low voltage 2006/95/EC
EMC 2004/108/EC
8. TROUBLESHOOTING & SOLUTION
My Thermostat doesn’t work
Power supply
- Check the power supply
My Thermostat show an Error message “
Err
” blink on the display
“
Error
” on sensor
Note:
For safety if there is a problem on the regulation sensor the
regulation will be replaced by a rate of 5 % functioning.
The logo and the text “
Err
” blinks. Error detected on
the internal sensor
- Contact your installer or seller.
My
Thermostat
seems work correctly but the heating doesn’t work correctly
Output
- Check the connections.
- Check the power supply of the heating element.
- Contact your installer.
My
Thermostat
seems work correctly but the temperature in the room was never in accordance with the program.
Program
- Check the Clock.
-The difference between Comfort & Reduced temperature
is too high?
- The step in the program is too short?
- Check the pilot wire function.