Technotherm PH Ultraslim Instruction Manual Download Page 4

Feel good through warmth from electricity - www.technotherm.de

Instruction Manual -   PH Ultraslim

Feel good through warmth from electricity - www.technotherm.de

GB

4|

•  TIMER MODE

The Timer mode allows you to adjust the temperature and the duration for a specific time.

 

- This function can be used when you stay at home for several days, or if you want to override  

 

   the programfor some time.

 

- You can first adjust the duration in hours “H” if below 24H, then in days “d” with (-) or (+),  

 

   press (OK) toconfirm. (Adjustable from 1 hour up to 44 days)

 

- You can also adjust the desired setting temperature to start the function. (Default value 24°C).

The     logo shines. By pressing the button “OK” the number of hours /days remaining is displayed until 

the end of the period.

If you want to stop the timer function before the end, set the duration period to “no” with (-) key.

•  MANUAL MODE COMFORT

Manual working mode, the comfort temperature setting will be followed 24 hours a day / 7 days a 

week. By pressing (-) or (+) keys, the temperature can be adjusted accordingly.

•  AUTOMATIC MODE

With this mode the thermostat will follow the chosen program (Built-in or customised) according to the 

actual time and the Comfort and Reduced temperature settings.

You can easily override the current program temperature by changing the value with (-) or (+). The 

current setting temperature will blink. The small hand         logo will be displayed when the override 

function is active. The original temperature settings will return when the timer reaches the next change 

in the programme.

If hand logo blinks then ITCS is active (See the user menu for more explanation on this function).

•  MANUAL MODE REDUCED

During manual working mode the reduced temperature setting will be followed 24 hours 

a day / 7 days a week. By pressing (-) or (+) keys, the temperature starts to blink and can 

be adjusted.

•  ANTIFREEZE MODE

Use this mode if you want to protect your radiator against freezing when going on holiday...

The anti-freeze setting temperature is fixed and can be adjusted in the parameter menu number 05 ‘AF’, 

see chapter 6 (default value 5°C).

•  TIME AND DATE ADJUSTMENT

See the paragraph of “TIME AND DATE ADJUSTMENT” described above.

5. PROGRAMMING WEEKLY

Select the mode      with the keys of displacement

When you enter in the Program mode, the first operation is to choose the program number using the 

(-) or (+) keys you can choose between a built-in program P1 to P9 or a user program U1 to U4. Select a 

program and press (OK) to validate.

Programm number

Day

Summary of Contents for PH Ultraslim

Page 1: ... www technotherm de 1 Model PH Ultraslim Instruction Manual PH Ultraslim THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE BE SURE TO OBSERVE ALL LABELS AND WARNINGS ON THE APPLIANCE Id Nr 900 370 411 Edition 01 18 ...

Page 2: ... dry radiators and can occur when the aluminium elements expand and contract Please note there is no danger to the user Children under 3 years old should be kept out of the equipment unless they are constantly supervised Children under 8 must only turn on off the device provided in normal position and only if they have received instruction concerning use of the equipment in a safe way and understa...

Page 3: ... a value blinks you can adjust it with the and keys Once the value is chosen confirm it with the OK key The thermostat will move automatically to the next value List order of the time and date adjustments 1 Time and day Adjustment of the hours Adjustment of the minutes Adjustment of the day 1 Monday 2 Date Adjustment of the day number Adjustment of the Month 01 January 12 December Adjustment of th...

Page 4: ...Comfort and Reduced temperature settings You can easily override the current program temperature by changing the value with or The current setting temperature will blink The small hand logo will be displayed when the override function is active The original temperature settings will return when the timer reaches the next change in the programme If hand logo blinks then ITCS is active See the user ...

Page 5: ...n Days working from 06 00 to 08 00 h and from 21 00 to 23 00 h Saturday from 18 00 to 24 00 h Sunday from 18 00 to 23 00 h P6 Comfort mode in Days working from 06 00 to 08 00 and from 14 00 to 20 30 h Weekend from 07 00 to 20 30 h P7 Comfort mode in Days working from 07 00 to 19 00 h Weekend Inactive P8 Comfort mode in Days working from 08 00 to 19 00 h Saturday from 08 00 to 18 00 h Sunday Inacti...

Page 6: ...ll of approximately 3 C it stops the heating for a period of 1 hour The icon will blink and the temperature will be measured by the ra diator Pressing any button at this stage will stop the detection of open windows The radiator will begin to function normally again and will restarts the detection of open windows POWER CONSUMPTION Select the mode with the keys of displacement In this screen you wi...

Page 7: ... key left Then the logo must disappear Pay attention Only the heating element managed by the thermostat must be used during the complete step of the calibration 7 ITCS Intelligent Temperature Control System The Intelligent Temperature Control System will activate your installation in advance 2 hours maximum to assure the desired temperature at the hour programmed following your weekly pro gram Thi...

Page 8: ...mostat was designed in accordance with the follo wing Europeans norms and directives EN 60730 1 2003 EN 61000 6 1 2002 EN 61000 6 3 2004 EN 61000 4 2 2001 Low voltage 2006 95 EC EMC 2004 108 EC 8 TROUBLESHOOTING SOLUTION My Thermostat doesn t work Power supply Check the power supply My Thermostat show an Error message Err blink on the display Error on sensor Note For safety if there is a problem o...

Page 9: ...ements Installation by an authorised person only CONNECTING ELECTRICITY SUPPLY If the Thermal Emitter that you have acquired does not have a plug on the supply cord installati on shouldbe carried out by a qualified electrician Means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules of thecountry where it is to be installed Before connecting check the su...

Page 10: ...se a hole drill for holes with appropriate stoppers for the type of wall 8 Place the radiator brackets in place using the supplied screws stoppers and washers 9 Approach the radiator to the brackets so that the grooves match with the ones on the bracket 10 Hang the radiator and secure it with the screws ...

Page 11: ...m occurring from such defects Allproblems arising from installing and undersized heater not enough heat improper installation etc are notcovered by this guarantee This heater is for domestic light commercial use only installation in any other environment voids thisguarantee Technotherm reserves the right to decide whether to repair or replace any defective part or to replace the entire heater All ...

Page 12: ...c 0 5 1 0 1 2 kW electronic heat charge control with room and or outdoor temperature feedback NO Auxiliary electrici ty consumption fan assisted heat output NO At nominal heat output elmax 0 9 1 5 2 0 kW Type of heat output room temperature control select one At minimum heat output elmin 1 2 1 2 1 2 kW single stage heat output and no room temperature control No 1 2 1 2 1 2 Two or more manual stage...