Information requirements for electric local space heaters

Model: PH Ultraslim

Item

Symbol

Value

Value

Item

Value

Heat output

Type of heat input, for electric storage local space heaters only (select one)

Nominal heat output

P

nom

0,9

1,5

2,0

kW

manual heat charge control, with integrated thermostat

NO

Minimum heat

output (indicative)

P

min

0,5

1,0

1,2

kW

manual heat charge control with room and/or outdoor temperature 

feedback

NO

Maximum continuo-

us heat output

P

max,c

0,5

1,0

1,2

kW

electronic heat charge control with room and/or outdoor

temperature feedback

NO

Auxiliary electrici-

ty consumption

fan assisted heat output

NO

At nominal heat 

output

el

max

0,9

1,5

2,0

kW

Type of heat output/room temperature control (select

one)

At minimum heat

output

el

min

1,2

1,2

1,2

kW

single stage heat output and no room temperature control

No

1,2

1,2

1,2

Two or more manual stages, no room temperature control

No

In standby mode

el

SB

1,2

1,2

1,2

kW

with mechanic thermostat room temperature control

N0

1,2

1,2

1,2

with electronic room temperature control

No

electronic room temperature control plus day timer

No

electronic room temperature control plus week timer

Yes

Other control options (multiple selections possible)

room temperature control, with presence detection

No

room temperature control, with open window detection

Yes

with distance control option

No

with adaptive start control

Yes

with working time limitation

No

with black bulb sensor

No

Contact Information:

Lucht LHZ Elektroheizung GmbG & Co. KG | Reinhard-Schmidt.Str.1  D-09217 Burgstädt

Summary of Contents for PH Ultraslim

Page 1: ... www technotherm de 1 Model PH Ultraslim Instruction Manual PH Ultraslim THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE BE SURE TO OBSERVE ALL LABELS AND WARNINGS ON THE APPLIANCE Id Nr 900 370 411 Edition 01 18 ...

Page 2: ... dry radiators and can occur when the aluminium elements expand and contract Please note there is no danger to the user Children under 3 years old should be kept out of the equipment unless they are constantly supervised Children under 8 must only turn on off the device provided in normal position and only if they have received instruction concerning use of the equipment in a safe way and understa...

Page 3: ... a value blinks you can adjust it with the and keys Once the value is chosen confirm it with the OK key The thermostat will move automatically to the next value List order of the time and date adjustments 1 Time and day Adjustment of the hours Adjustment of the minutes Adjustment of the day 1 Monday 2 Date Adjustment of the day number Adjustment of the Month 01 January 12 December Adjustment of th...

Page 4: ...Comfort and Reduced temperature settings You can easily override the current program temperature by changing the value with or The current setting temperature will blink The small hand logo will be displayed when the override function is active The original temperature settings will return when the timer reaches the next change in the programme If hand logo blinks then ITCS is active See the user ...

Page 5: ...n Days working from 06 00 to 08 00 h and from 21 00 to 23 00 h Saturday from 18 00 to 24 00 h Sunday from 18 00 to 23 00 h P6 Comfort mode in Days working from 06 00 to 08 00 and from 14 00 to 20 30 h Weekend from 07 00 to 20 30 h P7 Comfort mode in Days working from 07 00 to 19 00 h Weekend Inactive P8 Comfort mode in Days working from 08 00 to 19 00 h Saturday from 08 00 to 18 00 h Sunday Inacti...

Page 6: ...ll of approximately 3 C it stops the heating for a period of 1 hour The icon will blink and the temperature will be measured by the ra diator Pressing any button at this stage will stop the detection of open windows The radiator will begin to function normally again and will restarts the detection of open windows POWER CONSUMPTION Select the mode with the keys of displacement In this screen you wi...

Page 7: ... key left Then the logo must disappear Pay attention Only the heating element managed by the thermostat must be used during the complete step of the calibration 7 ITCS Intelligent Temperature Control System The Intelligent Temperature Control System will activate your installation in advance 2 hours maximum to assure the desired temperature at the hour programmed following your weekly pro gram Thi...

Page 8: ...mostat was designed in accordance with the follo wing Europeans norms and directives EN 60730 1 2003 EN 61000 6 1 2002 EN 61000 6 3 2004 EN 61000 4 2 2001 Low voltage 2006 95 EC EMC 2004 108 EC 8 TROUBLESHOOTING SOLUTION My Thermostat doesn t work Power supply Check the power supply My Thermostat show an Error message Err blink on the display Error on sensor Note For safety if there is a problem o...

Page 9: ...ements Installation by an authorised person only CONNECTING ELECTRICITY SUPPLY If the Thermal Emitter that you have acquired does not have a plug on the supply cord installati on shouldbe carried out by a qualified electrician Means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules of thecountry where it is to be installed Before connecting check the su...

Page 10: ...se a hole drill for holes with appropriate stoppers for the type of wall 8 Place the radiator brackets in place using the supplied screws stoppers and washers 9 Approach the radiator to the brackets so that the grooves match with the ones on the bracket 10 Hang the radiator and secure it with the screws ...

Page 11: ...m occurring from such defects Allproblems arising from installing and undersized heater not enough heat improper installation etc are notcovered by this guarantee This heater is for domestic light commercial use only installation in any other environment voids thisguarantee Technotherm reserves the right to decide whether to repair or replace any defective part or to replace the entire heater All ...

Page 12: ...c 0 5 1 0 1 2 kW electronic heat charge control with room and or outdoor temperature feedback NO Auxiliary electrici ty consumption fan assisted heat output NO At nominal heat output elmax 0 9 1 5 2 0 kW Type of heat output room temperature control select one At minimum heat output elmin 1 2 1 2 1 2 kW single stage heat output and no room temperature control No 1 2 1 2 1 2 Two or more manual stage...