Technosoft 2007
8
IPS110 Technical Reference
2.5. Electrical Specifications
All parameters measured under the following conditions (unless otherwise noted):
T
amb
= 0…40
°
C, logic supply V
LOG
= 5 V
DC
, motor supply V
MOT
= 24 V
DC
;
Supplies start-up / shutdown sequence:
-any-
;
Load current 0. 5 A
RMS
External DC-bus capacitor located 10cm from J1
Logic Supply Input
Measured bV
LOG
and GND.
Min.
Typ. Max.
Units
Nominal values
4,8
5
5,2
V
DC
Supply voltage
Absolute maximum values, continuous
†
-0.5 5,2 V
DC
Supply current
Normal operation
180
250
mA
Motor Supply Input
Measured bV
MOT
and GND.
Min.
Typ. Max.
Units
Operating voltages, including ripple &
braking-induced over-voltage
12 45 V
DC
Absolute maximum values, continuous
0
48
V
DC
Supply voltage IPS110
Absolute maximum values, surge
(duration
≤
10mS)
†
-0.5 50 V
DC-bus capacitor value
DC-bus capacitor connected between
+V
MOT
and GND
220 µF
DC-bus capacitor location
Wire length from DC-bus capacitor to
J1 pins
0 10 20 cm
Motor Outputs
All voltages referenced to GND.
Min.
Typ. Max.
Units
Motor output current
Continuous operation
-
+0.5
A
RMS
Motor output current, peak
-
+1
A
Short-circuit protection threshold
Programmable
Short-circuit protection delay
Programmable
On-state voltage drop
Output current =
±
0.5A
-
±
0.6
- V
Off-state leakage current
-1
±
0.1
+1 mA
F
PWM
= 20kHz, +V
MOT
= 12V
50
μ
H
Motor inductance
F
PWM
= 20kHz, +V
MOT
= 45V
200
μ
H
Summary of Contents for IPS110