![Technosoft IBL2403 Series Technical Reference Download Page 25](http://html.mh-extra.com/html/technosoft/ibl2403-series/ibl2403-series_technical-reference_1070590025.webp)
©
Technosoft 2007
15
IBL2403 Technical Reference
Others
Min.
Typ. Max.
Units
Operating 0
40
°
C
Temperature
Storage (not powered)
-40
85
°
C
Operating 0
90
%RH
Humidity (Non-condensing)
Storage 0
100
%RH
Altitude (referenced to sea level)
0 ÷ 1
+4
Km
Altitude / pressure
12
Ambient Pressure
0.64
0.9 ÷ 1
4.0
atm
Dimensions
Length x Width x Height
65 x 58 x 19
mm
Weight
0.1
Kg
Protection degree
IP20 (according to IEC529)
1
“FS” stands for “Full Scale”
†
Stresses beyond values listed under “absolute maximum ratings” may cause permanent damage to the device.
Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
T.B.D. = To be determined
Figure 2.12.
De-rating with ambient temperature
13
14
Figure 2.13.
De-rating with altitude
12
At altitudes over 1,000m, current and power rating are reduced due to thermal dissipation efficiency at higher altitudes.
See Figure 2.13 – De-rating with altitude
13
I
NOM
– the nominal current
14
Stand-alone operation, vertical mounting
Summary of Contents for IBL2403 Series
Page 2: ......
Page 4: ......
Page 8: ... Technosoft 2007 VI IBL2403 Technical Reference ...
Page 89: ......
Page 90: ......