Installation: Commissioning
- Cello 6 Wizard: Channel configuration
Step 6 - Configure channels.
- The initial "Configure Channels" page is now displayed.
- Set the logging rate at which the Cello 6S logs the data collected from the meter to
which it is attached. This is can be set between the minimum rate of 1 minute ("1 min")
and the maximum rate of 1 hour (typically a 30 minute ("30 min") logging rate is
applied).
- Select the required logging rate from the drop down box by highlighting the required
value.
- Where the Cello 6S has the "FLxm / RSD" flying lead input / output cable option fitted
then a replication of the inputs applied at channel 1 ("Ch1") may be output (refer to the
"Installation: Standard connections - inputs / output" section of this document for further
details).
- Where the option for replicated outputs is required then the "p/o" box is to be ticked.
- Be aware that where this option is selected then the channel 2 ("Ch2") input is no longer
available.
- Cello 6S can have a maximum of two inputs with the channel 1 ("Ch1") pulse input
always being enabled.
- The installer then has the option of having a second pulse input on channel 2 by ticking
the "Ch2" box, or having a meter status input (where the attached meter has a 'tamper'
circuit built-in) by ticking the "Tamper" box. The unit may be left as a single channel
channel device by not ticking either the "Ch2" or "Tamper" boxes.
- Note as above, where the channel 1 replicated output option "p/o" has been selected
then the channel 2 input is no longer available.