Summary of Contents for Cello 6S

Page 1: ...ights reserved Information contained in this document subject to change without prior notice Sheet 1 of 41 Technolog Limited Ravenstor Road Wirksworth DE4 4FY United Kingdom T 44 0 1629 823611 E techn...

Page 2: ...el configuration 19 Installation Commissioning Cello 6 Wizard Setting the time 20 Installation Commissioning Cello 6 Wizard Meter settings 23 Installation Commissioning Cello 6 Wizard Alarm settings G...

Page 3: ...r 3G UMTS mobile telecommunications networks Environment The Cello 6S water is specifically for use in non hazardous indoor and outdoor locations both above and below ground in ambient temperatures in...

Page 4: ...plosion and are potentially a severe burn hazard The cell contents are harmful by ingestion inhalation skin contact cause headache dizziness nausea and prolonged exposure may result in liver damage wh...

Page 5: ...curity tag s Local communications COMMs connection Option Input cable Mil Spec compatible MC03 connector termination Recess for fitting of optional user label Option Input cable un terminated flying l...

Page 6: ...prior notice Sheet 6 of 41 Technolog Limited Ravenstor Road Wirksworth DE4 4FY United Kingdom T 44 0 1629 823611 E technolog technolog com www technolog com DMR No 7311 2137PM9001 Rev A Features cont...

Page 7: ...s document subject to change without prior notice Sheet 7 of 41 Technolog Limited Ravenstor Road Wirksworth DE4 4FY United Kingdom T 44 0 1629 823611 E technolog technolog com www technolog com DMR No...

Page 8: ...that the necessary permissions are in place to allow entry before proceeding Be aware that to prevent the ingress of moisture and debris the lid must not be left off for any longer than is absolutely...

Page 9: ...ironment by suitably trained competent personnel in accordance with the applicable code s of practice Step 1 Ensure the gasket seal is clean un damaged and is in good condition clean and or replace wh...

Page 10: ...Noting orientation for replacement re fitting carefully remove the SIM card taking care not to catch the PCB mounted antenna where fitted Step 4 When re fiiting the SIM card ensure that it is clean an...

Page 11: ...tep 2 Attach a Technolog Fast Barrier Unit FBU complete with either a CBLBS04P000 x or CBLBS04P001 x output cable to the COMMs connector Step 1 Remove the protective cap from the local communications...

Page 12: ...type i e connector or flying lead the inputs may be connected to other equipment that provides a volt free output either in the form of switch closure or open collector The maximum frequency that may...

Page 13: ...nnected Contact Technolog for further infomation and details of antennas that are already approved for use with Cello 6S Use of any un approved external antenna with Cello 6S could lead to a potential...

Page 14: ...f this manual It also to be ensured that the computer laptop tablet you are using has the latest release of Technolog Cello 6 Wizard software installed contact Technolog for details and that it has be...

Page 15: ...nstallation Commissioning Cello 6 Wizard Startup Commissioning process Step 1 Select the Cello 6 Wizard icon on your PC laptop tablet Step 2 Once you have selected the software the software s Welcome...

Page 16: ...gnal strength On the display you will see the cellular network s detected by the modem with the strongest base station readings first with the readings being updated approximately every five seconds u...

Page 17: ...lue Where the Cello 6S has the FLxm RSD flying lead input output cable option fitted then a replication of the inputs applied at channel 1 Ch1 may be output refer to the Installation Standard connecti...

Page 18: ...e instructed to either send only that day s daily index reading by ticking the Send today s meter reading box or to send all daily index readings since the last successful data send by ticking the Sen...

Page 19: ...ablet being used to setup the Cello 6S as well as the time and date and the date and time already setup in the Cello 6S already setup in the Cello 6S itself If the time and or date of the two clocks a...

Page 20: ...2137PM9001 Rev A Installation Commissioning Cello 6 Wizard Meter settings Step 8 Meter settings The initial Meter settings page is now displayed although the content will depend on the options selecte...

Page 21: ...ding all alphanumeric characters of the meter attached to the Pulse inputs of the Cello 6S in the Meter 1 text box this box can accept up to 13 characters Typically the meter outputs one pulse for a g...

Page 22: ...of this manual type the full serial number including all alphanumeric characters of the meter attached to the Tamper inputs of the Cello 6S in the Meter 2 text box this box can accept up to 13 charact...

Page 23: ...General Step 9 Alarm settings The Cello 6S has a choice of two different alarm types Flow high low alarms Daily usage high low alarms Any channel s enabled at the Installation Commissioning Cello 6 Wi...

Page 24: ...ted whilst ever the flow rate is exceeded A set high value Currently High and or where there is a normal to high transition in the flow rate Normal High and or where there is a high to low transition...

Page 25: ...com DMR No 7311 2137PM9001 Rev A Where the Daily usage alarm type is selected type the required high low limits in the text boxes provided note the values can also be increased decreased using the up...

Page 26: ...Road Wirksworth DE4 4FY United Kingdom T 44 0 1629 823611 E technolog technolog com www technolog com DMR No 7311 2137PM9001 Rev A Installation Commissioning Cello 6 Wizard Alarm settings Finalising U...

Page 27: ...Service Limited UDSL Technolog Message Service Centre TMSC is shown Review the fields and when they are are set as required select Next Where GPRS communication is required first select the GPRS opti...

Page 28: ...d that the telephone number of the Cello 6S is sent as the identifier then the Use Default Values box is to be ticked Where this option is selected all remaining fields will be greyed out and not acce...

Page 29: ...l not be greyed out in the SMS Number field Regardless of configuration the telephone number of the fitted SIM card is entered in full including international code is automatically entered by the Cell...

Page 30: ...is required that even though the Cello 6S will only send its data weekly by clicking the Daily Wakeup box it will wake up and listen for any SMS configuration messages being sent to it thereby allowin...

Page 31: ...will only send its date weekly by clicking the Daily Wakeup box it will wake up and listen for any SMS configuration messages being sent to it thereby allowing remote over the air setup and changes t...

Page 32: ...per day at 6am However this option is programmable by Technolog either at the factory during manufacture or remotely once installed although when programmed its name will change to whatever has been r...

Page 33: ...lo 6 Wizard Dialout settings Finalising Review the allocated Dialout settings and when they are set as required select Next Step 13 Finish All configurable options should now have been set as required...

Page 34: ...311 2137PM9001 Rev A Installation Commissioning Cello 6 Wizard Finishing Step 13 Finish All configurable options should now have been set as required however where you are unsure select Back to revisi...

Page 35: ...the phone number of the installed SIM card Cello time the time and date of the Cello 6S when the report was generated FEP the version of firmare currently installed on the Cello 6S Modem the version...

Page 36: ...tails With the Cello 6 Wizard software displaying the Welcome page select Push data The software will now indicate all communication steps in the process of sending all the stored data in the Cello 6S...

Page 37: ...ignal strength section of this manual with the Cello 6S being moved around until the strongest signal strength is obtained although be aware that it may not be physically possible to locate it in the...

Page 38: ...structures In order to determine optimal Cello 6S performance a signal strength test should be perfomed as detailed in the Installation Commissioning Cello 6 Wizard Signal strength section of this ma...

Page 39: ...ot les than 20mm Please contact Technolog where Cello 6S is required to fit in boundary boxes other than that shown Note Where the Cello 6S does not feature an external antenna connector i e it only h...

Page 40: ...on of this manual the main body houses the circuit board internal antenna SIM card and replaceable battery pack Temporarily removing the lid allows access to the battery pack and SIM card As standard...

Page 41: ...ttery pack is to be disposed of in a safe and environmentally sound manner Refer to the Precautions Lithium battery packs cells section of this document for further details Step 4 Before fitting the n...