ACTIVE WTV: Machine configuration
1.2.1. L
OW KIT PARAMETER
This function provides access to parameters used for modifying certain settings of the lower
assembly. To access this menu, when the display shows:
In addition to the 13 configuration parameters, this function also includes the 3 sub-functions
described below:
1.2.1.1.
Read from low kit
To read the parameter values from the low kit memory and view them on the display, press
READ
FROM LOW KIT
key.
1.2.1.2.
Write to low kit
To write the values of the currently displayed parameters to the low kit, press
WRITE TO LOW
KIT
key.
1.2.1.3. Default
Setting
To load the default parameter values, press
DEFAULT SETTING
key.
1.2.1.4. Table of configuration parameters
To correctly display the parameter values, you need to load them from the low kit, using
the “Read from low kit” function.
Parameter Description
Range
Default value
Par
01
Default speed for Quick Start workout.
[Km/h*10]
0 - 300
8
Par 02
Default acceleration and deceleration for tread
belt motor. [Km/h*100/sec]
0 - 3000
100
Par 03
Default zero reference position for tread-belt
incline. [*2]
-10 - +40
0
Par 04
PID proportional gain. [*100]
0 - 9999
7
Par 05
PID Integral gain. [*100]
0 - 9999
150
Par 06
Ramp Type
0 - 100
0
Par 07
Error status on DC motor encoder
0 - 1
0
Par 08
Serial communication timeout [10*msec]
0 - 255
0