background image

 

ACTIVE WTV: Machine configuration

 

Page 18 

MENU –P– 

Par. 

Address Description 

Value  Par. 

Address Description 

Value 

P-45 411 

Motor thermal K 

30 

P-323

458 Autocap f scan  

10 

P-60 412 

V/f shape 

P-324

459 Autocap V scan  

P-61 413 

Max out voltage 

230  P-325

460 Enc for FlyRes 

P-62 414 

Base frequency 

600  P-326

461 Fre for FlyRes 

P-63 415 

V/f interm volt 

115  P-340

462 Undervoltage thr 

50 

P-64 416 

V/f interm freq 

300  P-341

463 Max pwrloss time 

P-80 417 

Max output freq 

100  P-342

464 UV alarm storage 

P-81 418 

Min output freq 

P-360

465 OV prevention 

P-100 419 

Slip compensate 

90 

P-380

466 Autoreset attmps 

P-101 420 

Slip comp filter 

P-381

467 Autoreset clear 

10 

P-120 421 

Manual boost [%] 

30 

P-382

468 Autoreset delay 

50 

P-121 422 

Boost factor src 

P-383

469 Autores flt rly 

P-122 423 

Auto boost en 

P-400

470 Ext fault mode 

P-140 424 

Magn curr gain 

30 

P-420

471 Volt reduc mode 

P-160 425 

Osc damping gain 

10 

P-421

472 V reduction fact 

100 

P-180 426 

SW clamp enable 

P-422

473 V fact mult src 

P-200 427 

Ramp CurLim mode 

P-440

474 Frequency thr 1 

P-201 428 

Curr lim in ramp 

170  P-441

475 Freq prog 1 hyst 

P-202 429 

En lim in steady 

P-442

476 Frequency thr 2 

P-203 430 

Curr lim steady 

P-443

477 Freq prog 2 hyst 

P-204 431 

Curr ctrl P-gain 

P-460

478 Const speed tol 

P-205 432 

Curr ctrl I-gain 

P-461

479 Const speed dl 

P-206 433 

Curr ctr feedfwd 

P-480

480 Heatsnk temp lev 

70 

P-220 434 

En DC link ctrl 

P-481

481 Heatsnk temp hys 

P-221 435 

DC-lnk ctr Pgain 

P-500

482 Switching freq 

P-222 436 

DC-lnk ctr Igain 

P-501

483 Sw freq reduc en 

P-223 437 

DC-link ctr FF 

P-520

484 Overmod max lev 

P-240 438 

OverTorque mode 

P-540

485 Out Vlt auto adj 

P-241 439 

OT curr lim thr 

P-560

486 Deadtime cmp lev 

P-242 440 

OT level fac src 

P-561

487 Deadtime cmp slp 

50 

P-243 441 

OT signal delay 

P-580

488 Startup display 

P-260 444 

Motor OL prot en 

P-600

489 Speed dsply fact 

100 

P-280 445 

Brake res OL en 

P-999

490 Param prot code 

 

 

1.2.9.   U

P

D

OWN SETTINGS

 

This function allows access to the parameters in the UpDown table which define the number of 
encoder pulses that correspond to different machine incline positions. To access this menu, when 
the LED display shows: 

Summary of Contents for ACTIVE Wellness TV RUN EXCITE

Page 1: ...ACTIVE Wellness TV 15 Display RUN EXCITE Machine configuration...

Page 2: ......

Page 3: ...ion parameters 9 1 2 2 Operating data 10 1 2 2 1 Read from low kit 10 1 2 2 2 Write to low kit 10 1 2 3 Errors log 11 1 2 3 1 Read from low kit 11 1 2 3 2 Reset Errors 11 1 2 3 3 COM Fault 11 1 2 4 TV...

Page 4: ...1 10 Troubleshooting service menu for 700 and 900 models 30 1 10 1 I2C Device Test 31 1 10 2 CSafe COM test 31 1 10 3 Low Kit COM Test 31 1 10 4 TGS COM Test 31 1 10 5 UpDown Test 32 1 10 6 Inverter...

Page 5: ...the proper password To access the menu type in the password 2406 and press ENTER key to confirm or BACK key to back forward At this point the machine display will shows the different parameters of th...

Page 6: ...kg and km or IMPERIAL units pounds and miles To change the selection select the desired option among the ones in the list directly touching on the Touch Screen MEASURE KM default MILES Press HOME to...

Page 7: ...ouch Screen TGS ENABLED default DISABLED Press HOME to confirm and save FORWARD or BACK to scroll the pages 1 1 7 KEYS It is possible to disable the keyboard so that the machine can only be used with...

Page 8: ...EST WEIGHT LOSS CUSTOM SPEED Press HOME to confirm and save FORWARD or BACK to scroll the pages 1 1 10 MODIFIABLE TARGET HEART RATE It is possible to enable or disable modification of the target heart...

Page 9: ...1 1 14 USER DETECT This function is able to detect the presence of a user running on the tread belt during an exercise session It is possible to configure a minimum speed at which the machine will de...

Page 10: ...mount of time in minutes the machine will wait before activating the screen saver with values ranging from 10 to 360 To change the setting press the MODIFY key and insert the value using the numeric k...

Page 11: ...the channel which is displayed on the TV when the TV is in standby To change the setting press the MODIFY key and insert the value using the numeric keyboard Press ENTER key to confirm or BACK key to...

Page 12: ...proper password To access the menu type in the password 2501 and press ENTER key to confirm or BACK key to back forward At this point the machine display will shows the different parameters of the men...

Page 13: ...ess WRITE TO LOW KIT key 1 2 1 3 Default Setting To load the default parameter values press DEFAULT SETTING key 1 2 1 4 Table of configuration parameters To correctly display the parameter values you...

Page 14: ...roll the pages 1 2 2 OPERATING DATA This function makes it possible to access the machine usage data stored in the low kit In addition to the machine usage data this function also includes the 2 sub f...

Page 15: ...o read the parameter values from the low kit memory and view them on the display press READ FROM LOW KIT key 1 2 3 2 Reset Errors To clear the error history in both the low and high kit memory press R...

Page 16: ...ad caused by a DC current exceeding for the maximum allowed time I2 t the maximum permissible threshold for the motor in question OLr 12 Braking resistor overload Ot 13 Over torque due to an even mome...

Page 17: ...a Norway Pakistan Poland Portugal Romania Singapore Slovakia Slovenia Spain Sri Lanka Sweden Switzerland Thailand Turkey 1 PAL B G United Arab E Zambia Zimbabwe Botswana Hong Kong Ireland South Africa...

Page 18: ...rt the power supply voltage provided by the electrical mains line 1 2 7 STANDARD SETTINGS This function clears the operating data of the machine and simultaneously resets the User menu low kit UpDown...

Page 19: ...111 1226Roller Diameter 91 A 8 1208PID update time 0 A 50 1209PID Prop gain 1 7 A 115 1227 DCMot EncTimeout AT driver SW 2 07 15 A 51 1210PID Int tconst 1 150 A 116 1228Fan command dly 3 A 52 1211PID...

Page 20: ...8h D 152 22 Vir dig out sta 0 D 956 56 Startup id code 0h D 170 23 Exp Dig out status 0 D 957 71 Drive type 2 D 171 24 Exp Drv dig out sta 0 D 999 99 Display test D 172 25 Exp Vir dig out sta 0 MENU F...

Page 21: ...e 0 I 210 123 An in 2 Type 1 I 750 163 SBI address 3 I 211 124 An in 2 offset 0 I 751 164 CAN baudrate 0 I 212 125 An in 2 gain 100 I 752 165 SBI Profibus mod 2 I 213 126 An in 2 minimum 0 I 753 166 S...

Page 22: ...ct mult src 0 P 200 427 Ramp CurLim mode 0 P 440 474 Frequency thr 1 0 P 201 428 Curr lim in ramp 170 P 441 475 Freq prog 1 hyst 5 P 202 429 En lim in steady 0 P 442 476 Frequency thr 2 0 P 203 430 Cu...

Page 23: ...the motor for example when one of the two components is replaced it is necessary to launch an autotuning function which analyses its phase resistance Carry out the operation by setting parameter C 100...

Page 24: ...egisters Incorrect programming of the AT driver may cause serious damage to the machine or result in malfunctions potentially dangerous to the user Therefore only attempt to program the inverter if yo...

Page 25: ...configuration menus using the proper password To access the menu type in the password 2407 and press ENTER key to confirm or BACK key to back forward At this point the partial screen TV is displayed...

Page 26: ...w the frequency column it is possible to scroll the frequency pages and using the and buttons below the channel numbers column it is possible to scroll the pages of the 39 channels which can be memori...

Page 27: ...at left can perform certain adjustments on the Wellness TV In particular it is possible to 1 Increase or reduce the brightness of the LCD 2 Increase or reduce the contrast of the LCD 3 Press the SAVE...

Page 28: ...e different configuration menus using the proper password To access the menu type in the password 2408 and press ENTER key to confirm or BACK key to back forward At this point the partial screen TV is...

Page 29: ...e STOP SEARCH key 3 Using the and buttons below the frequency column it is possible to scroll the frequency pages and using the and buttons below the channel numbers column it is possible to scroll th...

Page 30: ...ENTER to confirm or DELETE to cancel 3 Press the number that you want to associate the frequency If a channel has already been memorised under that number the old channel will be overwritten with the...

Page 31: ...l the channel configuration data to be saved to the key 4 Exit the menu by pressing the HOME key On the machine to be tuned 1 Enter the configuration menu of the channels that need to be tuned 2 Inser...

Page 32: ...e bottom left hand and the bottom right hand corner in sequence as shown in the picture below The machine display will shows a window from where you can access the different configuration menus using...

Page 33: ...or Calibration incomplete if the procedure was not completed properly after which the machine reverts to standby mode During the machine power up sequence while the message showing the installed softw...

Page 34: ...r in sequence as shown in the picture below The machine display will shows a window from where you can access the different configuration menus using the proper password To access the menu type in the...

Page 35: ...as negative The CSafe COM test done on a machine which CSafe port is not plugged with the monitor plug described at chapter 4 of the Service Maintenance manual 1 10 3 LOW KIT COM TEST The test checks...

Page 36: ...r test checks the condition of the AT driver The test can have two outcomes Test Successful This means that the test was completed successfully and the inverter is not in an error condition Inverter E...

Page 37: ......

Page 38: ...TECHNOGYM S p A Via G Perticari 20 47035 Gambettola FC ITALIA Tel 39 0547 650638 Fax 39 0547 650150 e mail service technogym com...