ACTIVE WTV: Machine configuration
Page 10
Parameter Description
Range
Default value
Par 09
DC motor encoder error timeout. [msec]
0 - 255
15
Par 10
FREE
-
0
Par 11
Driving roller diameter. [mm]
0 - 1000
91
Par 12
Pulley ratio
0 - 9000
200
Par 13
Error status on AC motor encoder
0 - 1
0
To change the setting, press the
CHANGE
key and insert the value using the numeric keyboard.
Press
ENTER
key to confirm or
BACK
key to back forward.
After any changes to the parameter values, you need to load them in the low kit using
the “Write to low kit” function.
Press
HOME
to confirm and save,
FORWARD
or
BACK
to scroll the pages.
1.2.2. O
PERATING DATA
This function makes it possible to access the machine usage data stored in the low kit.
In addition to the machine usage data, this function also includes the 2 sub-functions described
below:
1.2.2.1.
Read from low kit
To read the parameter values from the low kit memory and view them on the display, press
READ
FROM LOW KIT
key.
1.2.2.2.
Write to low kit
To write the values of the currently displayed parameters to the low kit, press
WRITE TO LOW
KIT
key.
The machine usage data on the display is updated every 10 minutes. This means that, whenever the
machine is switched off, any data modified after the last memory update will be lost.
To correctly display the parameter values, you need to load them from the low kit, using
the “Read from low kit” function.