Pump
: Pump power in percent. Use the buttons
/
to decrease / increase the power, when the
output is on.
Errors
When an error is registered, the controller goes to
shutdown state if it is in Burn state.
The only exception is error
Overheat Bunker
.
When it occurs, the controller goes straight to Clean
state even if the work mode is OFF.
The possible errors are:
■
Temp sensor
: Temperature sensor (from t1 to
t4) is either broken or shorted (according to the error
description).
■
Ignition failed
: The device failed to ignite.
■
No pellets
: The pellet level sensor has
determined that there is no more fuel and refill time
has expired.
■
Cleaner
: The cleaner mechanism is not in the
right position according to the level input sensor (
I3
).
■
Burning stopped
: In Burn state, a loss of
flame is detected according to the flue gases
temperature or light intensity.
■
Power failure
: The power was cut for time
exceeding the recovery time.
■
Feeder blocked
: The current, consumed by
the feeder is above the threshold.
■
Fume pressure
: error input
E2
activated.
■
Clock
: Error occurred in the real time clock
module. Does not force the device shutdown.
■
Overheat
: Overheating is registered in some of
the following modules (according to error
description):
▹
Water
: boiler temperature exceeded the
maximum.
▹
Flue
: flue gases temperature exceeded
maximum.
▹
Bunker
: error input
E1
activated.
Actions
The possible errors are:
■
Pow Supply ON
: Device connected to power.
■
Pow Supply OFF
: Device disconnected from
power.
■
Mode ON
: Device switched to ON mode.
■
Mode AUTO
: Device switched to AUTO mode.
■
Mode OFF
: Device switched to OFF mode.
■
Service Menu
: Service menu accessed.
■
Service
: Device serviced.
16
Service parameters