3.  Operation sequence in liquids leak detection mode 

Fig. 3.1

CAUTION!! 
During  leak  detection  works  one  should  have  a  detailed  diagram  of  underground 
utilities.  If  there  is  no  diagram,  a  preliminary  pipeline  route  location  should  be 
conducted. The level of valid signal and signal interference depends on the accuracy 
of acoustic sensor placement over the pipeline axis. 

Check the charge status of the batteries (

the charge 

should be no less than 4,0 V

). If the battery charge is low, 

replace the batteries

Check the accuracy of 

sensor connection. If a «no 

sensor» symbol is lit on the 

display  

,,check if the 

sensor is connected 

Select the received 

signal type «leak» 

 

by any of 

▲/▼

buttons

Set the necessary 

level of receiver display 

backlighting, using 

 ◄/► 

buttons

Equipment used:

3.

In the start window on the receiver display:

2.

 Turn on the 

Receiver AP-027

1. 

 Connect acoustic sensor and 

headphones to the corresponding 

receiver connections

3.1 Connection of sensors and check the receiver operability

 Leak detection АP-027

(10-06-15)

Acoustic sensor 

AD-227

Receiver 

AP 027

Headphones

Summary of Contents for Success AT-407N

Page 1: ......

Page 2: ...f operation Water leak detector Success 407N is designed for water leak detection from metal or plastic pipelines at depths of up to 6 m underground water leak detection from the pipelines inside the...

Page 3: ...5 filter button broadband on off 12 headphones jack 6 memory button 13 sensors connector 7 start pause button measurement mode 14 protective insert Technical specifications of the Receiver are listed...

Page 4: ...axis Check the charge status of the batteries the charge should be no less than 4 0 V If the battery charge is low replace the batteries Check the accuracy of sensor connection If a no sensor symbol i...

Page 5: ...in the spots where the signal level is the highest 7 We recommend you to record the points where signal level is the highest into the memory of the device by pressing the memory button 7 1 Browse the...

Page 6: ...er to enter the review mode 1 Turn off measurement mode by pressing 2 Press the memory button 3 Review memorized fields using the buttons In order to leave memory mode press button you enter the launc...

Page 7: ...alid signal and lowest number of light stripes interference signifies correct choice of filter 10 Switch to Scale mode by pressing visual indication button Without changing the settings examine the su...

Page 8: ...ected modes and parameters animated scale for input signal level numeric value and animated scale of output signal level graph moving diagram of the output signal level output signal frequency spectru...

Page 9: ...ed battery and the device will automatically switch off after type of the sensor connected Sensor not connected Acoustic sensor AD Electromagnetic sensor EMD type of signal received when working with...

Page 10: ...output overload Filtering Displays the frequency range scales with numerical and graphical representation of the pass band During work with AD pass band filter broadband DuringworkwithEMD central freq...

Page 11: ...lue of the signal in the mode current value of the signal in the mode and maximum current value of the signal for the previous second pulse amplitude 5 Acoustic signal spectrum window It displays the...

Page 12: ...can be called for by pressing the button The display shows the industrial frequency spectrum of 0 40 8 60 kHz Two segment columns display the current and minimum values of the frequency components of...

Page 13: ...y natural sound is used When working with EMD in the mode natural sound to the phones the adopted highactive frequency8192Hzand33kHz beforeplaying areconvertedintoawell acceptable low frequencies of 8...

Reviews: