background image

12

DEVELOPMENT, PRODUCTION, DELIVERY
Detection and locating, measuring equipment, water leak detectors, cable locators, cable and pipe locators  

6. Power range spectrum window

The window is available in the electromagnetic mode 

of  broadband 

  and  can  be  called  for  by  the 

additional  touch  of  a  button 

.  The  display  shows 

the  industrial  frequency  spectrum  of  «10  ...  640  Hz».  
Maximum of emission spectrum of the power cable falls 
to 50/60 Hz.

  Two-segment columns show the current and minimum 

values  of  the  frequency  components  of  the  signal. 

Typically, the spectrum contains harmonic components 

which are dependent on the form of voltage and current in the load. There can be often present 
strong odd harmonic components at frequencies of 150/180, 250/300 (Hz), etc.

7. Broadband electromagnetic spectrum window

The window is available in the electromagnetic mode 

of  broadband 

    and  can  be  called  for  by 

pressing the button 

. The display shows the industrial 

frequency spectrum of «0.40…8.60 kHz».

      Two-segment  columns  display  the  current  and 

minimum  values  of  the  frequency  components  of  the 
signal.

8.  Memory window 

Fig. А.6

Fig. А.7

value of the valid signal level

Number of memory 

cells. Selection of 

memory cells is 

performed by 

◄/► 

buttons 

levels of useful signal, fixed by memory buttons 

pressings

The receiver has an ability to record/view 

30  saved  signal  levels  (fig.А.8).    Output 
signal level values are recorded every time 
the  memory  button 

  pos.  6.fig.2.1  is 

pressed in the measurement  mode.

The memory of the receiver provides 30 

cells  for  filling,  any  subsequent  record  is 
the last one.

The  review  mode  is  called  up  by  the 

memory button    .

Fig. А.8

In order to do that:

  turn off measurement  mode by pressing 

, the start/pause button  , 

review memorized fields using 

◄/►

 buttons.

Leaving Memory window for the previous measurement mode occurs by sequentially pressing 

memory button    and measurement 

 buttons.

When the receiver is powered off, the recorded data is not saved.

Summary of Contents for Success AT-407N

Page 1: ......

Page 2: ...f operation Water leak detector Success 407N is designed for water leak detection from metal or plastic pipelines at depths of up to 6 m underground water leak detection from the pipelines inside the...

Page 3: ...5 filter button broadband on off 12 headphones jack 6 memory button 13 sensors connector 7 start pause button measurement mode 14 protective insert Technical specifications of the Receiver are listed...

Page 4: ...axis Check the charge status of the batteries the charge should be no less than 4 0 V If the battery charge is low replace the batteries Check the accuracy of sensor connection If a no sensor symbol i...

Page 5: ...in the spots where the signal level is the highest 7 We recommend you to record the points where signal level is the highest into the memory of the device by pressing the memory button 7 1 Browse the...

Page 6: ...er to enter the review mode 1 Turn off measurement mode by pressing 2 Press the memory button 3 Review memorized fields using the buttons In order to leave memory mode press button you enter the launc...

Page 7: ...alid signal and lowest number of light stripes interference signifies correct choice of filter 10 Switch to Scale mode by pressing visual indication button Without changing the settings examine the su...

Page 8: ...ected modes and parameters animated scale for input signal level numeric value and animated scale of output signal level graph moving diagram of the output signal level output signal frequency spectru...

Page 9: ...ed battery and the device will automatically switch off after type of the sensor connected Sensor not connected Acoustic sensor AD Electromagnetic sensor EMD type of signal received when working with...

Page 10: ...output overload Filtering Displays the frequency range scales with numerical and graphical representation of the pass band During work with AD pass band filter broadband DuringworkwithEMD central freq...

Page 11: ...lue of the signal in the mode current value of the signal in the mode and maximum current value of the signal for the previous second pulse amplitude 5 Acoustic signal spectrum window It displays the...

Page 12: ...can be called for by pressing the button The display shows the industrial frequency spectrum of 0 40 8 60 kHz Two segment columns display the current and minimum values of the frequency components of...

Page 13: ...y natural sound is used When working with EMD in the mode natural sound to the phones the adopted highactive frequency8192Hzand33kHz beforeplaying areconvertedintoawell acceptable low frequencies of 8...

Reviews: