3. Scale window

When  measurement  mode  is  selected  (except  the  two-frequency),  Scale  working  window 

appears first fig.А.3. 

Fig. А.3

Visual indication button can lead to the indication modes 

 of Graph (fig.А.4) and Acoustic 

signal spectrum(fig.А.5) or Power range spectrum  (fig.А.6)  and  Broadband electromagnetic 
range (fig.А.7).

Sensitivity

 

 - sensitivity symbol

«_dB»

 -the value of input 

amplification factor(0…62dB 

adjusted by using  

/

 ) 

- ensitivity scale

Two-segment scale

reflects the processed signal

Light segment:

- in the           mode 

 -current  

value of the signal (valid + 
interference):
- in the mode 

 - current 

value of the signal for the previous 

second (pulse amplitude).

Dark segment:

-in the mode 

- level of the 

processed valid signal;
- in the modes 

 and 

 -current signal 

level(valid+ interference)

A completely filled scale 

signifies output overload

Filtering

Displays the frequency range 

scales with numerical and graphical 

representation of the pass band

During work with AD:

 -  pass band filter
 - broadband

During work with EMD:

- central frequency of the 

narrow band filter 

- broadband

Presence of the indicator  

 signifies   

possibility of filter parameter 

adjustment.. The filter is switched on 

and off by using the filter button  

   

Scale

Contains a amplification 

factor value

 ×

1/2/4/8. 

   - indicator of buttons used

▲/▼

Sound

 - «natural» sound in the 

headphones (volume level 1to 8 

can be adjusted by 

◄/►

buttons)

 

 --«synthesized» sound to 

headphones (volume level 1 to 8 can 

be adjusted by  

◄/►

buttons)

  

 - «synthesized» sound in built-in 

speaker (volume level of the built-in 

speaker can not be adjusted).

Narrow scale

Displays the level of 

input signal 

A filled upscale signifies input 

overload. Overload can be 

eliminated and the optimal level of 

input signal can be set by using the

 

 /

  

Figure

Displays the level of

 processed 

signal

-  in  the  mode 

  -  valid  signal 

level value
-  in  the  mode 

  -    current 

signal level value

- in the modes 

  and 

   - 

maximum current signal level value 

for  the  previous  second  (pulse 

amplitude)

Summary of Contents for Success AT-407N

Page 1: ......

Page 2: ...f operation Water leak detector Success 407N is designed for water leak detection from metal or plastic pipelines at depths of up to 6 m underground water leak detection from the pipelines inside the...

Page 3: ...5 filter button broadband on off 12 headphones jack 6 memory button 13 sensors connector 7 start pause button measurement mode 14 protective insert Technical specifications of the Receiver are listed...

Page 4: ...axis Check the charge status of the batteries the charge should be no less than 4 0 V If the battery charge is low replace the batteries Check the accuracy of sensor connection If a no sensor symbol i...

Page 5: ...in the spots where the signal level is the highest 7 We recommend you to record the points where signal level is the highest into the memory of the device by pressing the memory button 7 1 Browse the...

Page 6: ...er to enter the review mode 1 Turn off measurement mode by pressing 2 Press the memory button 3 Review memorized fields using the buttons In order to leave memory mode press button you enter the launc...

Page 7: ...alid signal and lowest number of light stripes interference signifies correct choice of filter 10 Switch to Scale mode by pressing visual indication button Without changing the settings examine the su...

Page 8: ...ected modes and parameters animated scale for input signal level numeric value and animated scale of output signal level graph moving diagram of the output signal level output signal frequency spectru...

Page 9: ...ed battery and the device will automatically switch off after type of the sensor connected Sensor not connected Acoustic sensor AD Electromagnetic sensor EMD type of signal received when working with...

Page 10: ...output overload Filtering Displays the frequency range scales with numerical and graphical representation of the pass band During work with AD pass band filter broadband DuringworkwithEMD central freq...

Page 11: ...lue of the signal in the mode current value of the signal in the mode and maximum current value of the signal for the previous second pulse amplitude 5 Acoustic signal spectrum window It displays the...

Page 12: ...can be called for by pressing the button The display shows the industrial frequency spectrum of 0 40 8 60 kHz Two segment columns display the current and minimum values of the frequency components of...

Page 13: ...y natural sound is used When working with EMD in the mode natural sound to the phones the adopted highactive frequency8192Hzand33kHz beforeplaying areconvertedintoawell acceptable low frequencies of 8...

Reviews: