4. Graph window

The graph displays the changes in processed signal levels over time and moves at constant 

speed from right to left.

The graph

shows processed signal

-  in mode 

 -  change in the level of processed valid signal over time

 - in modes 

  and  

  - change in the level of current signal value over time 

Narrow scale

Displays the level of input signal.

A filled upscale signifies input overload. 

Overload can be eliminated and  he 

optimal level of  input signal can be set 

by using the 

 /

  

Figure

Displays the level of processed signal 

- in the mode 

 valid value of the signal

- in the mode 

 - current value of the signal

- in the mode 

  and 

   maximum current value of the signal for the previous second (pulse amplitude)

5. Acoustic signal spectrum window 

It displays the spectrum of the filtered signal. 
When working with EMD switching the window can have the following view :

Fig. А.4

Fig. А.5

dark segments 

correspond  to the frequency 

components of valid 

(«continuous») signal

light segments 

correspond to frequency 

components of accidental 

interference

Band pass of the filter on the figure - 0,21…0,95kHz. It is possible to switch over 

to adjusting the image scale at vertical  by means of 

▲/▼

 and volume in headphones 

by

◄/►

. it is possible to switch over to adjusting the pass band and vise versa by means of 

(

→◄/►→

). 

The frequencies at which light segments significantly predominate over dark probably are the 

interference frequencies to be suppressed by the band pass filter.

Summary of Contents for Success AT-407N

Page 1: ......

Page 2: ...f operation Water leak detector Success 407N is designed for water leak detection from metal or plastic pipelines at depths of up to 6 m underground water leak detection from the pipelines inside the...

Page 3: ...5 filter button broadband on off 12 headphones jack 6 memory button 13 sensors connector 7 start pause button measurement mode 14 protective insert Technical specifications of the Receiver are listed...

Page 4: ...axis Check the charge status of the batteries the charge should be no less than 4 0 V If the battery charge is low replace the batteries Check the accuracy of sensor connection If a no sensor symbol i...

Page 5: ...in the spots where the signal level is the highest 7 We recommend you to record the points where signal level is the highest into the memory of the device by pressing the memory button 7 1 Browse the...

Page 6: ...er to enter the review mode 1 Turn off measurement mode by pressing 2 Press the memory button 3 Review memorized fields using the buttons In order to leave memory mode press button you enter the launc...

Page 7: ...alid signal and lowest number of light stripes interference signifies correct choice of filter 10 Switch to Scale mode by pressing visual indication button Without changing the settings examine the su...

Page 8: ...ected modes and parameters animated scale for input signal level numeric value and animated scale of output signal level graph moving diagram of the output signal level output signal frequency spectru...

Page 9: ...ed battery and the device will automatically switch off after type of the sensor connected Sensor not connected Acoustic sensor AD Electromagnetic sensor EMD type of signal received when working with...

Page 10: ...output overload Filtering Displays the frequency range scales with numerical and graphical representation of the pass band During work with AD pass band filter broadband DuringworkwithEMD central freq...

Page 11: ...lue of the signal in the mode current value of the signal in the mode and maximum current value of the signal for the previous second pulse amplitude 5 Acoustic signal spectrum window It displays the...

Page 12: ...can be called for by pressing the button The display shows the industrial frequency spectrum of 0 40 8 60 kHz Two segment columns display the current and minimum values of the frequency components of...

Page 13: ...y natural sound is used When working with EMD in the mode natural sound to the phones the adopted highactive frequency8192Hzand33kHz beforeplaying areconvertedintoawell acceptable low frequencies of 8...

Reviews: