5
HYSTERESIS
is the
temperature at which it switches off again - This is the “hysteresis”. Without this hysteresis - your
FAN AND HEATER would keep switching on and off every few seconds.
difference between the temperature at which the heater switches on - and the
Button Functions and General controller displays
Enters HEATER temperature setting and also doubles as the
button.
Hold this button down for 5 seconds to adjust HEATER HYSTERISIS.
DOWN
FAN Button
HTR/
Button
DOWN
TEMP/
Button
UP
RH Button
Press to set the minimum and maximum run speed of your fans.
Press the
min
/
max
button to switch between min and max fan run speed settings.
Enters the
DESIRED ROOM HUMIDITY SETTING
.
Enters the
DESIRED ROOM TEMPERATURE
SETTING
and also doubles as the
button.
UP
ADJUSTABLE HYSTERESIS:
Fan
Heater
Temp
R/h
Htr
Min
Max
Fan
Power
Evolution
Humidity
Temperature
Digital Fan Speed Controller
DOWN
UP
Min/Max Button
Left LED display
Function: To swap between min and max fan speed settings.
note: only works after
you have pressed the FAN button
Displays live Temperature reading from the sensor probe.
This display is multi functional when programming user settings.
Right LED display
Displays live Humidity reading from the sensor probe.
This display is multi functional when programming user settings.
FAN LED light
The blue Fan light flashes to show that your Fans are currently running,
the faster the flashing indicates a higher speed and constantly lit light
indicates 100% fan speed, slower blinking indicates slower or idle fan
speed.
Heater LED light
The Red Heater light indicates that the Heater is now active.
Power LED light
The Green Power light indicates that the Evolution Digital Fan Speed
Controller is powered up from the mains supply.