Stat Out
(Thermostat Output)
This output connects to the stat input
(thermostat input) of the Evolution Co2
controller if this controller is working
together with the Co2 controller.
Note this output is only used in
conjunction with the Evolution CO2
Controller.
Wire: 0.5mm - 0.75mm
A - Stat Out
B - Heater Out
D - Fan 1
C - Fan 2
E - Power Input
F - Sensor Input
Htr Out
(Heater Output)
This output can control Heater loads up to
a maximum of 3Kw.
Wire: 1.25mm - 1.5mm
Fan 1
This output is for the Air IN fans. Multiple
fans can be used with a maximum
combined load of 6Amps.
Wire: 0.75mm
Fan 2
This output is for the Air OUT fans. Multiple
fans can be used with a maximum
combined load of 6 Amps.
Wire: 0.75mm
Power Input
This is the main power supply to the
controller and should have a minimum
1.25mm cable with a 13 Amp supply or
higher.
Wire: 1.25mm - 1.5mm
Sensor
The sensor is supplied with a 5M cable and
plugs into the small telephone type socket.
Wire: Included with temperature sensor.
L
N
L
N
L
N
L
N
Fan 1
Power
Input
L
N
Heater
B
L
N
Stat
Output
A
C
D
E
Fan 2
Sensor
Rear view of the Evolution Digital Fan Speed Controller with the cover off
Sensor
Socket
F
Technics
Evolution
Digital Fan Speed
Controller
neutral - Blue wire
earth - green & yellow wire
live - Brown wire
Connections
This appliance must be installed by an approved electrician
and must be connected via an approved RCD safety breaker.
SAFETY CONSIDERATIONS