– 25 –
Indoor Unit : SPA480R5TAA Outdoor Unit : GR480R7TAA
TC : Total Cooling Capacity (kW)
SHC : Sensible Heat Capacity (kW)
CI : Compressor Input (kW)
Rating conditions (#MARK) : Outdoor Ambient Temperature 35
°
C DB
Indoor Unit Entering Air Temperature 27
°
C DB / 19
°
C WB
RATING CAPACITY : 14 kW AIR FLOW RATE : 1920 m
3
/h
EVAPORATOR CONDENSER
ENT. TEMP.
°
C AMBIENT TEMP.
°
C
WB DB 25 30 35 40 45
TC 14.13 13.48 12.8 12 11.14
CI 3.72 3.97 4.27 4.15 4.05
21 SHC 9.3 8.9 8.5 8.1 7.7
15 23 SHC 10.3 9.9 9.6 9.1 8.7
25 SHC 11.3 10.9 10.6 10.2 9.7
27 SHC 12.3 12 11.6 11.2 10.8
29 SHC 13.3 13 12.6 12 11.14
31 SHC 14.13 13.48 12.8 12 11.14
TC 14.6 14.01 13.36 12.64 11.86
CI 3.81 4.09 4.38 4.28 4.17
21 SHC 8 7.7 7.3 7 6.6
23 SHC 9 8.7 8.4 8 7.6
17 25 SHC 10 9.7 9.4 9 8.7
27 SHC 11 10.7 10.4 10.1 9.7
29 SHC 12 11.7 11.4 11.1 10.7
31 SHC 13.1 12.8 12.4 12.1 11.7
TC 15.12 14.57 #14 13.3 12.54
CI 3.93 4.21 4.52 4.42 4.33
21 SHC 6.6 6.4 6.1 5.8 5.5
23 SHC 7.7 7.4 7.2 6.8 6.5
19 25 SHC 8.7 8.4 8.2 7.9 7.5
27 SHC 9.7 9.5 9.2 8.9 8.6
29 SHC 10.7 10.5 10.2 9.9 9.6
31 SHC 11.8 11.5 11.2 10.9 10.6
TC 15.61 15.06 14.49 13.83 13.16
CI 4.04 4.33 4.65 4.56 4.47
23 SHC 6.3 6.1 5.9 5.6 5.3
21 25 SHC 7.4 7.1 6.9 6.6 6.3
27 SHC 8.4 8.2 7.9 7.6 7.4
29 SHC 9.4 9.2 8.9 8.7 8.4
31 SHC 10.4 10.2 10 9.7 9.4
TC 16.14 15.67 15.12 14.56 13.89
CI 4.15 4.44 4.77 4.69 4.61
23 25 SHC 6 5.9 5.6 5.4 5.2
27 SHC 7.1 6.9 6.7 6.5 6.2
29 SHC 8.1 7.9 7.7 7.5 7.2
31 SHC 9.1 8.9 8.7 8.5 8.3
TC 16.8 16.21 15.72 15.18 14.59
CI 4.28 4.59 4.86 4.82 4.77
25 27 SHC 5.8 5.6 5.4 5.2 5
29 SHC 6.8 6.6 6.4 6.2 6
31 SHC 7.8 7.6 7.4 7.3 7.1
1. SPECIFICATIONS