6.4 - LP PRESSURE SWITCH KIT for GRV 265 X only -
Code K 60 G 094 Z
7 - CONNECTING ACCESSORIES
8 - STANDARD CONTROL TYPE 523
Cut-off value: 0.5 bar. Non-adjustable. Automatic reset.
• Install the pressure switch directly on the suction piping pressure
tapping (see drawing opposite).
• If no HP pressure switch is already connected, remove the jumper
between terminals 5 and 6 of the main terminal strip and connect the two
pressure switch wires in their place.
• If the HP pressure switch is already connected between terminals 5 and
6 of the main terminal strip, disconnect the wire of terminal 6 and connect
it to a wire of the LP pressure switch, by using the double male lug
supplied with the LP kit. Connect the second wire of the LP pressure
switch on the terminal 6, now free.
Important: This connection must be made inside the electrical box.
6.5 - "PROPORTIONAL" HEAD PRESSURE CONTROL
for GRV 265 X only - Code K 60 G 012 Z
• Fix the controller directly on the pressure tapping point provided (see drawing above).
• Insert the cable into the electric equipment cabinet through a cable gland.
• Remove the jumper between terminals 3 and 4 of the main terminal strip and connect the two wires of the controller in its place.
Main terminal strip
LP pressure switch
HP pressure switch
Condensing
pressure regulator
Accessories
terminal strip
• Heat pump models only
8.1 - PRINCIPLE
• The microprocessor manages the operation of the
air-conditioner.
• It constantly compares the ambient temperature with the
value displayed on the remote control. Each request for
operation processed by the controller is indicated by lights
7 and 8 (see paragraph 8.2.2).
These lights flash if a safety time delay is in progress.
It changes to a steady light when the unit is operating.
8.2 - PRESENTATION
8.2.1 - POWER SUPPLY CARD
• See wiring diagram for details on the
connections.
Remote
control
Electronic power
supply card
(in PA)
Actuators
Standby
contact
(possible)
Signalling
contact
(possible)
Remote ambient
thermoresistor
(option)
Defrosting sensor
(in GR-R)
Ambient
temperature
sensor
GR
fan control
PA
fan control
Cycle reverse
valve control
Compressor
control
Remote control
connection
Power supply 230 VAC
Defrosting sensor
Remote sensor
Make up
heating control
Standby
Signalling
7.1 - REFRIGERANT CONNECTIONS
(for CP(V) 188 only)
Length
Code
Unit
2 m
4 m
8 m
12 m
2 m
4 m
8 m
12 m
CPV 188 L
CP 188 R
CPV 188 L
CP 188 R
• These connections include the 2 insulated refrigeration lines.
7.2 - COMPLETE CONNECTION ASSEMBLIES
• These include: - the refrigeration lines,
- the electric cables,
- a condensate tube.
NOTE: The electric cables supplied in the connection assemblies cannot
be used for the reversible model.
K 70 A 02 BT
K 70 A 04 BT
K 70 A 08 BT
K 70 A 12 BT
K 70 A 02 BXT
K 70 A 04 BXT
K 70 A 08 BXT
K 70 A 12 BXT