1. Specifications
1
2
3
4
5
I - 89
●
Heating Capacity
15˚C
20˚C
25˚C
140
120
100
80
60
%
25˚C
20˚C
15˚C
140
120
100
80
60
%
–15
–10
–5
0
5
10
15
Comp. motor power input ratio
Heating capacity ratio
Outdoor temperature ˚C WB
Indoor temperature ˚C DB
Indoor temperature ˚C DB
0413_M_S
NOTE
1.
Above characteristics are based on:
1) Tubing length is 7 meters.
2) Air flow speed is high speed.
2.
Minimum outdoor ambient temperature: –15
°
C WB
3.
Above characteristics indicate instantaneous capacity. Integrated capacity is instantaneous
capacity less the effect of frost on the outdoor coil and the drop of performance during defrost
cycle.