5 - USING THE CONTROL BOARD

SWITCH

• This is for selecting the unit's functions.

• Turn the knob to the position the pointer on the required function.

See symbols on diagram :

-

Symbol 1

 : OFF

-

Symbol 2

 : Cooling function at low ventilation speed.

-

Symbol 3

 : Cooling function at medium ventilation speed.

-

Symbol 4 

: Cooling function at high ventilation speed.

-

Symbol 5 

: Ventilation function only at low speed.

-

Symbol 6 

: Ventilation function only at medium speed.

-

Symbol 7 

: Heating function at low ventilation speed.

-

Symbol 8 

: Heating function at medium ventilation speed.

THERMOSTAT :

• Set the required temperature by rotating the

thermostat knob. Turn the knob to the blue

area for lower temperatures and to the red

area for higher temperatures.

NOTE :

When the required temperature is reached,

only the ventilation continues to operate.

0

1

2

3

4

5

7

6

8

SWITCH

THERMOSTAT

6 - MAINTENANCE AND CLEANING

IMPORTANT

For safety reasons : switch off the air conditioner and disconnect from the mains before starting cleaning (see § 1).

Do not pour water onto the appliance to clean it. This could damage the internal components and cause electrical
discharges.

FRAME AND GRILLE

• Clean the frame and the grille of the appliance with a vacuum cleaner brush or with a soft, clean cloth

.

If these parts are dirty, clean them with a clean cloth moistened with a mild liquid detergent.

PRECAUTIONS

Never use solvents or powerful chemicals. Do not clean with very hot water.

Some metal edges and the fins on the heat exchanger are sharp and must be handled carefully during cleaning to
prevent injury.

Summary of Contents for AOF 15

Page 1: ...STRUCTIONS BEDIENUNGSANLEITUNG 10 11 590 F GB D 00 Mai 2012 AOF AOF 15 AOF 25 AOF 55 CLIMATISEUR MONOBLOC A CONDENSATION A EAU SINGLE PACKAGED ROOM AIR CONDITIONER WITH WATER COOLED CONDENSER KOMPAKT...

Page 2: ...2 F GB D...

Page 3: ...d admission d air de l ext rieur PRECAUTIONS Ne pas mettre en marche ou arr ter le climatiseur l aide de l interrupteur g n ral Employer seulement le bou ton de marche arr t I 0 Ne rien introduire dan...

Page 4: ...bouton vers la zone rouge NOTA Lorsque la temp rature souhait e est atteinte seule la ventilation tourne 0 1 2 3 4 5 7 6 8 COMMUTATEUR THERMOSTAT 6 ENTRETIEN ET NETTOYAGE ATTENTION Par s curit arr ter...

Page 5: ...sont ferm es pour viter des infiltrations d air non r frig r lorsque l appareil fonctionne en mode refroidissement A FILTRE Le bon fonctionnement du climatiseur exige un nettoyage r gulier du filtre...

Page 6: ...hermostat est r gl trop haut pour le refroidissement ou trop bas pour le chauffage Le pressostat HP a coup REMEDES 1 R tablir l alimentation 2 Prendre contact avec le Service Apr s Vente 3 Consulter v...

Page 7: ...r sick people in it 4 SAFETY INSTRUCTIONS 3 ELECTRICAL PRECAUTIONS Before installing make sure that the mains voltage is the same as the voltage indicated on the air conditioner s rating plate All the...

Page 8: ...es and to the red area for higher temperatures NOTE When the required temperature is reached only the ventilation continues to operate 0 1 2 3 4 5 7 6 8 SWITCH THERMOSTAT 6 MAINTENANCE AND CLEANING IM...

Page 9: ...are closed in order to prevent non cooled air entering when the appliance is operating in the cooling mode A FILTER If the air conditioner is to operate satisfactorily the air filter must be cleaned...

Page 10: ...r inlet or outlet 5 The thermostat is set too high for cooling or too low for heating The HP pressure switch has cutof f SOLUTIONS 1 Restore the supply 2 Contact the After Sales Department 3 Consult y...

Page 11: ...n Vertragsh ndler oder die zugelassene Kundendienststelle Die Klimaanlage dient zur Erzeugung eines angenehmen Raumklimas V erwenden Sie das Ger t ausschlie lich zu dem Zweck f r den es vorgesehen ist...

Page 12: ...nktion Ventilation nur mit mittlerer Drehzahl Nr 7 Funktion Warm mit kleiner Ventilationsdrehzahl Nr 8 Funktion Warm mit mittlerer Ventilationsdrehzahl 0 1 2 3 4 5 7 6 8 SCHALTER THERMOSTAT 6 WARTUNG...

Page 13: ...en ffnungen geschlossen sind um den Eintritt ungek hlter Luft zu vermeiden wenn das Ger t im K hlbetrieb arbeitet A FILTER F r den einwandfreien Betrieb des Klimager tes ist eine regelm ige Reinigung...

Page 14: ...ST RUNG Die Klimaanlage funktioniert berhaupt nicht das Gebl se schaltet sich nicht ein K hlung oder Heizung nicht ausreichend Der Verdichter l uft nicht an ABHILFEMASSNAHMEN 1 Stromzufuhr wiederherst...

Page 15: ...15 F GB D...

Page 16: ...avis Due to our policy of continuous development our products are liable to modification whitout notice Unsere Produkte werden laufend verbessert und k nnen ohne Vorank ndigung abge ndert werden Z I R...

Reviews: