1 - PRESENTATION

10

9

7

8

6

5

4

3

2

1

1

- Discharge grille

2

- Removable panel

3

- Front panel

4

- Inlet grille

5

- Rear support

6

- Side panel

7

- Control panel

8

- Control knobs

9

- Door

10

- Fixed panel

• Read this manual carefully before using the air conditioner for the first time. If you have any doubts or problems, consult the

dealer or the authorised After-Sales Department.

• This air conditioner has been designed to create comfortable climatic conditions. Only use it for the purpose for which it was

designed and according to the instructions indicated in this manual.

IMPORTANT

Never use or store petrol or any other flammable liquid near the air conditioner. This would be extremely dangerous.

This air conditioner is not equipped with an outside air intake fan.

PRECAUTIONS

Do not switch the air conditioner on or off using the main switch. Use only the on/off switch ( I / 0 ).

Do not put anything into the air conditioner's air intlet. This is very dangerous because the fan works at high
speed.

Do not let children play with the air conditioner.

Do not cool the room excessively when there are babies or sick people in it.

4 - SAFETY INSTRUCTIONS

3 - ELECTRICAL PRECAUTIONS

• Before installing, make sure that the mains voltage is the same as the voltage indicated on the air conditioner's rating plate.

• All the electric connections must comply with local regulations and be carried out by a qualified technician.

• Each unit must be correctly earthed with a good quality earth connection.

2 - INSTALLATION LOCATION

It is recommended that the air-conditioning unit be installed by a qualified technician, and in compliance with the
installation instructions supplied with the unit and as per all regulations in force and the code of practice.

IMPORTANT

Do not install the air-conditioning unit in premises where gases or inflammable gases are emitted, nor should it
be installed in a place that is damp or where there is a risk of water being projected (e.g., laundry room).

Do not install the air conditioner in places where there are appliances producing excessive heat.

Materials:

- Plastic coated sheet body.

- Steel grids.

- Felt insulation.

- Copper/aluminium air evaporator.

- Copper/steel water condenser.

- Copper piping.

MARKING

This product marked        conforms to the essential requirements of the Directives :

- Low voltage no. 2006/95/EC.

- Electromagnetic Compatibility no. 2004/108/EC.

- Pressure Equipment Directive No. 97/23/EC.

Summary of Contents for AOF 15

Page 1: ...STRUCTIONS BEDIENUNGSANLEITUNG 10 11 590 F GB D 00 Mai 2012 AOF AOF 15 AOF 25 AOF 55 CLIMATISEUR MONOBLOC A CONDENSATION A EAU SINGLE PACKAGED ROOM AIR CONDITIONER WITH WATER COOLED CONDENSER KOMPAKT...

Page 2: ...2 F GB D...

Page 3: ...d admission d air de l ext rieur PRECAUTIONS Ne pas mettre en marche ou arr ter le climatiseur l aide de l interrupteur g n ral Employer seulement le bou ton de marche arr t I 0 Ne rien introduire dan...

Page 4: ...bouton vers la zone rouge NOTA Lorsque la temp rature souhait e est atteinte seule la ventilation tourne 0 1 2 3 4 5 7 6 8 COMMUTATEUR THERMOSTAT 6 ENTRETIEN ET NETTOYAGE ATTENTION Par s curit arr ter...

Page 5: ...sont ferm es pour viter des infiltrations d air non r frig r lorsque l appareil fonctionne en mode refroidissement A FILTRE Le bon fonctionnement du climatiseur exige un nettoyage r gulier du filtre...

Page 6: ...hermostat est r gl trop haut pour le refroidissement ou trop bas pour le chauffage Le pressostat HP a coup REMEDES 1 R tablir l alimentation 2 Prendre contact avec le Service Apr s Vente 3 Consulter v...

Page 7: ...r sick people in it 4 SAFETY INSTRUCTIONS 3 ELECTRICAL PRECAUTIONS Before installing make sure that the mains voltage is the same as the voltage indicated on the air conditioner s rating plate All the...

Page 8: ...es and to the red area for higher temperatures NOTE When the required temperature is reached only the ventilation continues to operate 0 1 2 3 4 5 7 6 8 SWITCH THERMOSTAT 6 MAINTENANCE AND CLEANING IM...

Page 9: ...are closed in order to prevent non cooled air entering when the appliance is operating in the cooling mode A FILTER If the air conditioner is to operate satisfactorily the air filter must be cleaned...

Page 10: ...r inlet or outlet 5 The thermostat is set too high for cooling or too low for heating The HP pressure switch has cutof f SOLUTIONS 1 Restore the supply 2 Contact the After Sales Department 3 Consult y...

Page 11: ...n Vertragsh ndler oder die zugelassene Kundendienststelle Die Klimaanlage dient zur Erzeugung eines angenehmen Raumklimas V erwenden Sie das Ger t ausschlie lich zu dem Zweck f r den es vorgesehen ist...

Page 12: ...nktion Ventilation nur mit mittlerer Drehzahl Nr 7 Funktion Warm mit kleiner Ventilationsdrehzahl Nr 8 Funktion Warm mit mittlerer Ventilationsdrehzahl 0 1 2 3 4 5 7 6 8 SCHALTER THERMOSTAT 6 WARTUNG...

Page 13: ...en ffnungen geschlossen sind um den Eintritt ungek hlter Luft zu vermeiden wenn das Ger t im K hlbetrieb arbeitet A FILTER F r den einwandfreien Betrieb des Klimager tes ist eine regelm ige Reinigung...

Page 14: ...ST RUNG Die Klimaanlage funktioniert berhaupt nicht das Gebl se schaltet sich nicht ein K hlung oder Heizung nicht ausreichend Der Verdichter l uft nicht an ABHILFEMASSNAHMEN 1 Stromzufuhr wiederherst...

Page 15: ...15 F GB D...

Page 16: ...avis Due to our policy of continuous development our products are liable to modification whitout notice Unsere Produkte werden laufend verbessert und k nnen ohne Vorank ndigung abge ndert werden Z I R...

Reviews: