36
6. ELECTRICAL DATA
6-1. Electrical Characteristics
Indoor Unit MCAV180R5VAA
Outdoor Unit GRV180R7TAA
COOLING
Indoor Unit
Outdoor Unit
Complete Unit
Fan Motor
Fan Motor
Compressor
Performance at 230V 50Hz 400 V - 3N - 50Hz
Rating Conditions Running Amps. A 0.38 0.50 3.43 4.0
Power Input kW 0.072 0.093 2.002 2.15
Full Load Conditions Running Amps. A 0.38 0.50 3.81 4.6
Power Input kW 0.072 0.093 2.398 2.60
Rating Conditions
: Indoor Air Temperature 27°C D.B. / 19°C W.B.
Outdoor Air Temperature 35°C D.B.
Full Load Conditions : Indoor Air Temperature 32°C D.B. / 23°C W.B.
Outdoor Air Temperature 43°C D.B.
HEATING
Indoor Unit
Outdoor Unit
Complete Unit
Fan Motor
Fan Motor
Compressor
Performance at 230V 50Hz 400V - 3N - 50Hz
Rating Conditions Running Amps. A 0.38 0.50 3.32 4.2
Power Input kW 0.072 0.093 2.107 2.25
Full Load Conditions Running Amps. A 0.38 0.50 3.33 4.21
Power Input kW 0.072 0.093 2.285 2.45
Rating Conditions
: Indoor Air Temperature 20°C D.B.
Outdoor Air Temperature 7°C D.B. / 6°C W.B.
Full Load Conditions : Indoor Air Temperature 27°C D.B.
Outdoor Air Temperature 24°CD.B. / 18°CW.B.