background image

 

5

Unpacking 

Immediately upon receipt, carefully unpack and inspect the fixture to verify that all parts are 
present and have been received in good condition.  If any parts appear damaged from shipping 
or the shipping carton shows signs of mishandling, notify the shipper immediately.  Retain 
carton and all packing material for inspection.  In the event that the merchandise is to be 
returned, the original carton and packing must be used.  The customer will be billed for a new 
carton and packing if merchandise is received without the original carton and packing. 
 

Claims 

Physical damage must be reported to the Freight Carrier or Shipping Company upon 
receipt of merchandise.  Damage incurred in shipping is the responsibility of the Freight 
Carrier or Shipping Company.  It is the customer’s obligation in the event that 
merchandise is received damaged, to notify the Freight Carrier or Shipping Company 
immediately.  All other claims not related to damage incurred during shipping must be 
made to the Dealer or Distributor within 7 days of receiving merchandise.  

 

Returns 

Returned merchandise must be in the original packing with a Return Merchandise 
Authorization number (RMA) clearly listed on the shipping label.    Items sent by Freight 
Collect or without a RMA number will be refused.   Call your sales person and request a 
RMA prior to shipping.  Be prepared to provide the model number, serial number and 
description of the nature of the return.  Shipping damage resulting from inadequate 
packaging is the customer’s responsibility.  Customer will be charged additional shipping 
charges to return products received in non original packing and or cartons. 

 
 

Power 

 

Do not apply power to the fixture until power source is verified. 

 

For protection against electric shock, fixture must be connected to suitable earth ground. 
Make sure fixture is disconnected from power mains before any service. 

 
The mains voltage and frequency of this fixture is internally set. It can either be used at 120v or 
230v AC 50/60Hz.  The listed power rating is its average wattage under normal conditions. All 
fixtures must be powered directly from a switched circuit.  This fixture cannot be run on a 
rheostat or dimmer circuit even if used solely for a 0% to 100% switching.  Before applying 
power to a fixture, check that the fixture’s input voltage matches the power source voltage.  
Consult a qualified electrician if there are any concerns about proper connection to power. 
 
 

Mounting 

Always consult a qualified professional when rigging.  Consider access for routine maintenance 
when selecting a mounting position. This fixture may be mounted in any position provided there 
is adequate room for movement and ventilation.  Mount the fixture securely using a mounting 
clamp and a safety cable.  This fixture features dual yokes making it useful for floor standing at 
different angles. Always keep cords out of the way, thus preventing any trip hazards. Secure all 
cables properly. Do not mount where the fixture will be exposed to extreme temperature 
changes or restricted ventilation.  Do not obstruct any vents. 

Summary of Contents for Ultra LED Series

Page 1: ...Information specifically for DL LEDPAR3TC36O B Black V1 This manual contains important information Please read before operating fixture...

Page 2: ...o and shall not exceed the purchase price paid Returning equipment and Repairs All returns must be accompanied by a Return Merchandise Authorization RMA number and sent pre paid Contact the dealer or...

Page 3: ...Connection 8 Data Terminator 8 Adapter 5 to 3 pin 8 DMX Start Address 9 DMX Channel Assignments 9 3 Channel Mode 9 4 Channel Mode 9 5 Channel Mode 10 6 Channel Mode 10 Channel Values and Functions 6 C...

Page 4: ...ical Color Black Size 9 5 x 11 0 x 7 25 Weight 15 4 lbs 7 kgs Housing Material Aluminum Environmental Location Indoor Outdoor IP65 Max ambient temperature 105 F 40 C Min distance to flammable surface...

Page 5: ...return Shipping damage resulting from inadequate packaging is the customer s responsibility Customer will be charged additional shipping charges to return products received in non original packing an...

Page 6: ...the fixture s Control Panel to access the Control Menu The MENU Key puts the fixture in the settings menu itself and also acts as a BACK key between options UP DOWN moves through the menu options and...

Page 7: ...ress so the channels used do not overlap with other fixtures In some cases it may be desirable to set two or more same type fixtures to the same Start Address In this case the fixtures will be slaved...

Page 8: ...Negative S and pin 3 Data positive S A qualified technician can determine if a Data Terminator is needed Adapter 5 to 3 pin Systems using 5 pin DMX interfaces can be accommodated by purchasing 3 to 5...

Page 9: ...MX channel available for a Start Address is found by adding the previous fixture s Start Address to its channel requirement 1 6 7 To maximize channel usage we will leave no empty channels between fixt...

Page 10: ...intensity of Green Actual value is subject to Master Dimmer channels The Color Macro Scroll Channel will override this channel Channel Function 1 Red 0 255 2 Green 0 255 3 Blue 0 255 4 Master Dimmer 0...

Page 11: ...69 Lt Green 70 74 Green 75 79 Teal 80 84 Cyan 85 89 Color Scroll Snap Speed 1 Fastest 90 94 Color Scroll Snap Speed 2 95 99 Color Scroll Snap Speed 3 100 104 Color Scroll Snap Speed 4 105 109 Color Sc...

Page 12: ...Speed 11 225 229 Color Scroll FADE Speed 12 230 234 Color Scroll FADE Speed 13 235 239 Color Scroll FADE Speed 14 240 244 Color Scroll FADE Speed 15 245 249 Color Scroll FADE Speed 16 250 255 Color S...

Page 13: ...lements when the fixture is cold Use a soft lint free cotton cloth or tissue and cleaner safe for plastics 5 Inspect clamps and safety cables to ensure fixture is secure and safe Accessory Items sold...

Page 14: ...mitted one after another Even if the data on a specific channel has not been changed it must be sent In a packet a start code of all zeros is sent before the data to identify the signal as a Standard...

Reviews: