17
Oct/2017 - V1
Technetix Group Limited
Product User Manual
AIMA-FT5E
Item
Description
'BC Input Power' /
'NC Input Power' /
'RF Composite Input Power' / 'Laser
Temperature' /
'Laser Bias Current' /
'Laser Output Power'
Select or unselect parameters to determine alarm settings and levels. The settings for alarm threshold values
and blind spots can be selected.
See Table 5-2 for the default settings for each parameter.
'Submit'
Saves changes to settings.
Item
Description
'Auto Download'
Automatic downloading of the latest FT5E configuration files from the ASMM module to the
FT5E module.
'Auto Upload'
Automatic uploading of the FT5E’s current configuration files to the ASMM module’s database.
'Manual'
Manual setting of all parameters in the module configuration interface and module port configuration interface
(for details, see Chapters 5.1.1 and 5.1.2).
Table 5-2 FT5E default port alarm settings
5.1.3 Automatically Uploading/Downloading Module Config Files
Select 'Modules' on the AIMA3000 configuration system interface. Select 'All Modules' in the module list on the left side, as
shown in Figure 5-3.
Find the FT5E module in the [Module Type] in the white section on the right side. Details about the current configuration of
the FT5E can be accessed by clicking on [See Details]. Synchronisation of configuration files with the ASMM module can
be set in the [Hotswap Mode]:
Parameter
Unit
HiHi
Hi
Lo
LoLo
Blind
BC Input Power
dBmV
53. √
48.8 √
23.8 √
18.8 √
1.0
NC Input Power
dBmV
63
58.8
23.8
18.8
1.0
RF Composite Input Power
dBmV
59 √
57 √
47
45
1.0
Laser Temperature
°C
60 √
40 √
15 √
–15 √
0.5
Laser Bias Current
mA
15 √
120 √
20 √
15 √
0.2
Laser Optical Output Power
dBm
16 √
13 √
7 √
4 √
0.5
Note:
'√'
When the parameter value in the selected check box exceeds the threshold value, the corresponding level alarm is triggered. When the
value is between Hi and Lo threshold values, the alarm status is normal (no alarm). The secondary alarm is triggered if the Hi (Lo) threshold
value is exceeded. The main alarm is triggered if the HiHi (LoLo) threshold value is exceeded.