16
Oct/2017 - V1
Technetix Group Limited
Product User Manual
AIMA-FT5E
FT5E port configuration details include four parts: port information, status, configuration, and alarm settings.
Port Information (read-only); the displayed items and button functions are as follows:
Status (read-only); the displayed items are as follows:
Configuration; parameters and button functions are as follows:
Alarm Settings; parameters and button functions are as follows:
Item
Description
'Port Information'
Slot, module type, and port number.
'Refresh'
Refreshes the interface.
Item
Description
'Status'
Laser type, laser wavelength, laser output status, laser TEC current, AGC point, AGC status, broadcast input
power, narrowcast input power, RF composite input power.
Item
Description
'Laser Output Control'
'On'; enables the port’s laser optical output (default). 'Off'; disables the port’s laser optical output.
'Modulation Mode'
'CW'; continuous wave; CW is higher 2dB than Modulated. 'Modulated'; modulated wave (default).
'Input AGC Mode'
'On'; switches on the AGC mode; 'Off'; switches off the AGC mode (default).
'OMI Offset'
Range: –3.0 - 3.0 dB (default: 0 dB).
'Broadcast MGC'
Range: –10.0 - 5.0 dB (default: 0 dB).
'Narrowcast MGC'
Range: –10.0 - 5.0 dB (default: 0 dB).
'SBS Control'
'Enable': Enable the SBS Control. 'Disable': Disable the SBS Control. Default is Enable.
'Fibre link distance adjust'
Range: 0 - 60 Km (default: 20 Km).
'Submit'
Saves changes to settings.
Item
Description
'Laser Output Status Alarm'
'Set as the Main Alarm'; when the 'Laser Output Control' is 'off', the main alarm is triggered and the Parameter 3
'Laser Output' indicator light on the module’s alarm status interface (Chapter 5.2.2, Figure 5-5) is red.
'Set as the Secondary Alarm'; when the 'Laser Output Control' is 'off', the secondary alarm is triggered and the
Parameter 3 'Laser Output' indicator light on the module’s alarm status interface is orange.
'Prohibit Alarm'; when the 'Laser Output Control' is 'off', no alarm is triggered and the Parameter 3 'Laser Output'
indicator light on the module’s alarm status interface is green.
Default: 'Set as the Main Alarm'.