Manual TECHKON DENS

1.3 Design of DENS

DENS is a solidly designed measurement device which is very functional and easy to 
use. It is compact in size; the buttons can be reached with the index finger when the 
device is held. The display is clearly legible and a great advantage of DENS is, that it can 
be easily positioned on the measurement sample. 

The USB-connector is for battery charging. The mini-USB plug, which fits into the con-
nector at the side of the device, is part of the package. 

K

C

M

Y

80% 40% 0

K

C

M

Y

K

C

M

Y

80% 40%

0

K

C

K

C

K

C

M

Y

K

C

M

Y

K

C

M

Y

BAL

BAL

C+M

BAL

BAL

C+Y

M

Y

BAL

M+Y

BAL

0

BAL

K

5%

4%

3%

2%

80% 40%

80% 40%

80% 40%

80% 40%

80% 40%

MODE

  D = Density and gray balance in reflection

  D % = Dot % in reflection

  T = Density in transmission

  T % = Dot % in transmission

CAL

  Paper- or absolute 

  white calibration

DENS

  On

  Measurement 

  DENS turns automatically off 

  after one minute of inactivity

  Battery charge condition

  Measurement head with 2.5 mm aperture

  Display of the measured color

  USB port for chargings

  Magnifier

  Device label with 

  serial number

  Light button LENS

  of the magnifier

Summary of Contents for DENS

Page 1: ...Manual Color Densitometer DENS...

Page 2: ...can not fully guarantee the complete absence of errors TECHKON GmbH and the authors can not be held liable neither for any possibly incorrect statements nor their consequences Products that are not m...

Page 3: ...5 minutes you will know how to work with DENS The second chapter will show you detailed insight into the measurement functions Please get the device registered by using the registration card which you...

Page 4: ...orking with DENS 9 1 5 Care and maintenance 11 ChaptEr 2 Description of the measurement functions 2 1 Measurement function D 14 2 2 Measurement function D 15 2 3 Measurement function T 16 2 4 Measurem...

Page 5: ...amental densitometric quality control on the basis of the reliable high accuracy well known from all TECHKON instruments The DENS indicates densities dot area and gray balance clearly legible on a lar...

Page 6: ...user friendly measurement button Durable precision Handy and compact low weight Well designed Two different versions We supply TECHKON DENS in two device versions DENS Status ISO E Pol Density filter...

Page 7: ...manual A comprehensive DENS manual can be downloaded under www techkon com index php dens html Optional accessories Print Control Strip TECHKON TCS the Digital Print Control Strips TECHKON TCS can be...

Page 8: ...r at the side of the device is part of the package K C M Y 80 40 0 K C M Y K C M Y 80 40 0 K C K C K C M Y K C M Y K C M Y BAL BAL C M BAL BAL C Y M Y BAL M Y BAL 0 BAL K 5 4 3 2 80 40 80 40 80 40 80...

Page 9: ...ttery status is displayed as a battery symbol with three segments in the lower right corner of the display when the device is turned on When the battery turns empty the last remaining segment of the b...

Page 10: ...working properly For density measurements according to Status ISO E Pol the calibration is carried out on paper white This will ensure that the density values are in direct ratio to the ink thickness...

Page 11: ...y labels at the bottom of the device This could lead to faulty measurements because the direct contact which is important for the correct optical field of depth might not be maintained Warranty The wa...

Page 12: ...evice case 4 When reassembling do not tighten the screws too much otherwise they might break Replacement of the rechargeable battery The rechargeable Li Ion battery has a high lifespan However after a...

Page 13: ...ch of the reference and press the CAL but ton 3 Place the measurement head on the Cyan solid density patch of the reference and press the DENS button 4 The desired value can be set respectively by pre...

Page 14: ...tween 1 00 and 2 00 Chapter 2 Description of the measurement functions The current measurement function is indicated on the right side of the display A switch to the next mode is done by pressing the...

Page 15: ...posed of different portions of Cyan Magenta and Yellow It does not include black ink 1 Measurement 2 Measurement 2 2 Measurement function D Dot area measurement in reflection For the function Dot Area...

Page 16: ...he luminosity of the light table Av erage bright light tables allow you to measure densities up to D 4 00 and over Please note The emulsion side of the film has to be always on the upper side 2 4 Meas...

Page 17: ...nt time 0 5 seconds per measurement White reference Relative ISO E or absolute ISO T Density filter ISO E with polarization filter optional ISO T without polarization filter Density measurement range...

Page 18: ...s maintenance free The measurement aperture has to be kept clean from dust It can be cleaned with clean compressed air and an optics brush We recommend a functionality check up every 24 months at the...

Page 19: ...al standards DIN 5033 part 1 9 CIE and ISO 5 3 The accuracy of the device is checked during the manufactur ing by spectral measurements on color samples which were measured and certified by the German...

Page 20: ...anforderungen gem eu richtlinie 2004 108 ec entspricht und dass die folgenden Normen angewandt wurden complies with the essential requirements of the 2004 108 EC Directive if used for its intended us...

Page 21: ...Please put my E mail address on the mailing list for the TECHKON Newsletter TECHKON GmbH Wiesbadener Str 27 D 61462 K nigstein Via telefax to 49 0 6174 9244 99 Please send this registration card by ma...

Page 22: ...TECHKON GmbH Wiesbadener Str 27 D 61462 K nigstein T 49 0 6174 924450 F 49 0 6174 924499 info techkon com www techkon com Erfolg ist messbar...

Reviews: